Gas pre-flow and post-flow time is too long, Troubleshooting & repair, Caution – Lincoln Electric PRECISION TIG 275 SVM162-B User Manual

Page 62

Advertising
background image

F-16

F-16

PRECISION TIG 275

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-

tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

FUNCTION PROBLEMS

The AC wave balance control does

not function properly.

NOTE: BEFORE REPLACING A

CONTROL BOARD

If an Advanced Control Panel is

installed, remove it and replace

the Jumper in connector J-3. If

the machine functions normally,

the Advanced Process panel or

harness is defective.

1. The AC wave balance control is

operational only in the TIG mode.

1. Check the AC balance control

(R2) and associated leads for

loose or faulty connections. See

the Wiring Diagram.

2. The control board may be faulty.

Gas pre-flow and post-flow time is

too long.

1. If an advanced control board is

installed, check dip switch set-

ting on the board. See

Installation Manual.

1. Check plug J3 on the control

board. Either the jumper plug or

the advanced control board must

be plugged into J3.

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.