F-43

F-43

PRECISION TIG 275

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

TROUBLESHOOTING & REPAIR

0V

5 ms

20V

This is the typical AC output voltage

waveform generated from a properly

operating machine. Note that each ver-

tical division represents 20 volts and

that each horizontal division represents

5 milliseconds in time.
NOTE: Scope probes connected at

machine output terminals: (+) probe to

electrode, (-) probe to work.
NOTE: AC balance control set at

“Balanced” position.

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED TO 200 AMPS

DC - TIG MODE

HIGH VOLTAGE/ HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

Volts/Div......................20V/Div.

Horizontal Sweep......5 ms/Div.

Coupling..............................DC

Trigger..........................Internal

SCOPE SETTINGS