TROUBLESHOOTING & REPAIR

HIGH FREQUENCY CIRCUIT DISABLE PROCEDURE

Service and repair should be performed by only Lincoln Electric factory trained personnel.

Unauthorized repairs performed on this equipment may result in danger to the technician

or machine operator and will invalidate your factory warranty. For your safety and to avoid

electrical shock, please observe all safety notes and precautions detailed throughout this

manual.
If for any reason you do not understand the test procedures or are unable to perform the

test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-

bleshooting assistance before you proceed. Call 1-888-935-3877.

DESCRIPTION

This procedure will disable the high frequency circuit allowing the technician to take volt-

age measurements without the possibility of high frequency damage to his test equipment.

MATERIALS NEEDED

3/8” Nut Driver

Electrical Insulating Tape

WARNING