Operation – Lincoln Electric PRECISION TIG 275 SVM162-B User Manual

Page 21

Advertising
background image

B-5

OPERATION

B-5

• When the Polarity Switch is set to DC (- or +), the

TIG mode provides high frequency only for starting.

• Hi-Freq. turns on after pre-flow time with the arc

start switch closure, and turns off when the arc is

established*

• DC+ polarity can also be used for ”balling” of the

tungsten for AC TIG welding.

4. AC BALANCE CONTROL

– The potentiometer

control permits AC wave balance adjustment from

Max. Penetration (~85% negative wave) with the

control at Max. full CW position, to Max. Cleaning

(~65% positive wave) with the control set near min-

imum CCW position.

• Full minimum CCW position is the Auto Balance

position which is indicated by the Green panel light

turning on. This feature automatically provides the

proper amount of cleaning and penetration for nor-

mal AC TIG welding

• The mid position is the Balanced position (~50%

positive and negative waves).

• The Balance control is only functional if the machine

is set to AC polarity and TIG mode.

5. LOCAL/REMOTE

CURRENT CONTROL SWITCH

– A

2-position switch selects how the welding output is

controlled for both Stick and TIG Modes:

• LOCAL (Top position) selects output control only by

the machine panel Output Control. (See Item 6)

• REMOTE (Bottom position) selects output control to

also be by an Amptrol (See Item 6), or other remote

(10K pot) control connected to the Remote recepta-

cle (See Item 11) This switch selection is indicated

by the Green panel light turning on.

In either position the arc start switch functions when

connected to the Remote receptacle (See Item 11).

6. MAXIMUM OUTPUT CONTROL

– The large knob

is used to set the output welding current over the

rated output range of the machine.

• With the Current Control switch to LOCAL position,

this knob sets the welding output level.

• With the Current Control switch to REMOTE posi-

tion, this knob sets the maximum welding level that

the Peak output can be set with the remote Amptrol.

• The new MicroStart

TM

Technology minimum current

circuit provides for low end welding (down to 2

amps) previously unobtainable on an SCR platform

TIG machine.

7. MINIMUM OUTPUT CONTROL AND DISPLAY SWITCH

A smaller knob is used to preset the minimum cur-

rent level only for TIG mode. Pressing the Display

(momentary) switch toggle left to Minimum Set posi-

tion displays the Minimum control level setting on the

Digital meter. (See Item 8)

• This knob sets the Start output level. When the arc

lights (using a new built-in TIG start pulse) this level

upslopes quickly (0.5 sec.w/ Advanced Panel, zero

w/o) and smoothly to the weld output level. The set-

ting range for this Start control is the 2 amp mini-

mum range of the machine up to about 50 amps, but

no more than the level set by the Maximum Output

control knob (See Item 6), but otherwise is indepen-

dent of the Maximum setting.

• This setting also serves as the Crater-fill level, but

with a Precision TIG Advanced Panel it can be

selected (see Section B-7) to be either the Minimum

Output control setting (same as Start setting) as

shipped, or the minimum rating of the machine (2

amps).

• The Remote Amptrol range of control is between

this Minimum setting and the Maximum Output con-

trol knob setting, so these knobs can set the resolu-

tion of the Amptrol. Also, the Minimum setting

serves as both the minimum Amptrol start level

when the arc start switch is closed, as well as the

minimum Amptrol crater-fill level before the arc start

switch is opened to help prevent premature arc out

and Hi-Freq re-initiation.

.

• In STICK mode the Start control is not functional

since Hot Start level is fixed, or internal Advanced

Panel adjustable (see Section B-7). Pressing the

Display (momentary) switch toggle left to Minimum

Output position displays minimum amps rating of

the machine.

PRECISION TIG 275

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising