TROUBLESHOOTING & REPAIR

T1 MAIN TRANSFORMER TEST (continued)

TEST PROCEDURES

1. Using the 3/8” nut driver, remove the two screws

from the front control panel. Carefully lower the

panel. This will allow access to the control board.

2. Locate plug J11 on the control board. See Figure

F.4.

ELECTRIC SHOCK can kill.

*With input power ON, there are high voltages inside

the machine. Do not reach

into the machine or touch any

internal part.

...........................................................................
3. Carefully apply the correct input power making cer-

tain the reconnect configuration at the reconnect

panel is correct for the input voltage applied. Turn

the Precision TIG 275 ON.

4. Using the voltmeter, carefully test for the correct

transformer secondary voltages per

Table F.3.

5. Carefully check for 63.5 VAC at leads 267 to lead

268. Lead 268 is located at the background rectifi-

er.

Note: Lead 267 is located at resistor R8. See Wiring

Diagram.

6. Carefully check for 115 VAC at leads 231 to 232.

Note: Lead 231 is located at the 115 VAC recepta-

cle on the back of the machine. Lead 232 is

located at the 15 amp circuit breaker CB1.

7. If all of the secondary voltages are correct, the T1

transformer is functioning properly.

a. If all of the secondary voltages are missing or

incorrect, make certain that the correct input

voltage is being applied to the correct primary

leads.

See Table F.3.

b. If the correct input voltage is being applied to

the primary leads and any or all of the sec-

ondary voltages are incorrect, the T1 trans-

former may be faulty. Also check the leads for

broken or loose connections between plug J11

and the T1 transformer.

8. Replace the case side covers.

Figure F.4 Plug J11

263

214

204

210

266

253

270

220

209

262

265

201

252

269

271

213

Plug
J11

G3909

Plug
J11

WARNING

Advertising