Troubleshooting & repair, 0v 5 ms 20v – Lincoln Electric PRECISION TIG 275 SVM162-B User Manual

Page 86

Advertising
background image

F-40

F-40

PRECISION TIG 275

TROUBLESHOOTING & REPAIR

0V

5 ms

20V

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED TO 200 AMPS

AC - TIG MODE

HIGH VOLTAGE/ HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

This is the typical AC output voltage

waveform generated from a properly

operating machine. Note that each ver-

tical division represents 20 volts and

that each horizontal division represents

5 milliseconds in time. The machine

was loaded with a resistance grid bank.
NOTE: Scope probes connected at

machine output terminals: (+) probe to

electrode, (-) probe to work.

Volts/Div......................20V/Div.

Horizontal Sweep......5 ms/Div.

Coupling..............................DC

Trigger..........................Internal

SCOPE SETTINGS

AC BALANCE CONTROL IN “AUTO”

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising