TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-

tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

FUNCTION PROBLEMS

The meter does not display V (volt)

or minimum current.

NOTE: BEFORE REPLACING A

CONTROL BOARD

If an Advanced Control Panel is

installed, remove it and replace

the Jumper in connector J-3. If

the machine functions normally,

the Advanced Process panel or

harness is defective.

1. Check that either the advanced

control board or jumper plug is in

J3 on the control board.

1. Check R1 potentiometer and

associated leads between the

control board and plug J9. See

the Wiring Diagram.

2. The control board may be faulty.