Troubleshooting & repair, Caution – Lincoln Electric PRECISION TIG 275 SVM162-B User Manual

Page 53

Advertising
background image

The machine has welding output in

the Stick mode but no output in the

TIG mode. ( no gas flow or high fre-

quency).

SEE NOTE BELOW

1. Make sure the Stick/TIG switch

is in the proper position and

operating correctly.

2. The remote control device may

be faulty.

1. Check the remote control recep-

tacle and associated wiring. See

the Wiring Diagram.

2. Perform the

Protection Board

Test.

3. Check the J11 plug on the con-

trol board. See the Wiring

Diagram.

4. The control board may be faulty.

The machine welds at a very low

output regardless of the current

control setting.

NOTE: BEFORE REPLACING A

CONTROL BOARD

If an Advanced Control Panel is

installed, remove it and replace

the Jumper in connector J-3. If

the machine functions normally,

the Advanced Process panel or

harness is defective.

1. If welding in the TIG mode, the

remote control device may be

defective.

2. Make certain the input line volt-

age is correct for the machineʼs

reconnect configuration.

3. Check the welding cables and/

or torch for loose or faulty con-

nections.

1. Check the polarity switch and

associated leads.

2. Check the interior connections of

the heavy current carrying leads.

3. Perform the

SCR Bridge Test

.

4. Perform the

T1 Transformer

Test.

5. Check the output current con-

trols for proper operation.

Normal resistance is 10,000

ohms. See the Wiring Diagram.

6. The control board may be faulty.

F-7

F-7

PRECISION TIG 275

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

TROUBLESHOOTING & REPAIR

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-

tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

OUTPUT PROBLEMS

The machine does not have welding

output in the Stick mode. The

machine operates correctly in the

TIG mode.
SEE NOTE BELOW

1. Check the electrode cable and

holder for loose or faulty connec-

tions.

2. Make sure the Stick/TIG switch is

in the proper position and operat-

ing correctly.

1. Check the Stick/TIG switch and

associated leads. See the Wiring

Diagram.

2. The control board may be faulty.

CAUTION

Advertising