TROUBLESHOOTING & REPAIR

STATIC SCR TEST (continued)

TEST PROCEDURE

1. Remove main supply power to the PRECI-

SION TIG 275 and remove the case top and

left side.

2. Locate and remove plug J4 from the control

board. See Figure F.5.

3. Using an analog ohmmeter, test the resis-

tance from anode to cathode of SCR1.

Reverse the meter leads and check from

cathode to anode of SCR1. See Figure F.5. If

a low resistance is indicated in either direc-

tion, SCR1 is faulty. Replace the SCR Bridge

Assembly. See

SCR Bridge Assembly

Removal and Replacement.

4. Repeat Step #3 testing SCR2, SCR3 and

SCR4.

5. To further check the SCRʼs functions, use an

SCR tester and proceed to the

Active SCR

Test.

NOTE: Also check diode D1.

6. Replace plug J4 on the control board.
7. Replace the case top and left side.

Plug
J4

G3909

Figure F.5 - Plug J4 Location

DIODE D1

SCR4 CATHODE

SCR3 / SCR4 ANODE

SCR3 CATHODE

SCR2 ANODE

SCR1 / SCR2 CATHODE

SCR1 ANODE

LIFT BAIL STABILIZER

Figure F.6 - SCR TEST POINTS