Setting the clean slot option – Plasmon V15 User Manual

Page 43

Advertising
background image

Configuration

Page 41

3. Press the down arrow key until “SCSI Parity” displays, as shown below. This screen shows

whether parity is enabled (1) or disabled (0).

4. Press [ENTER]. The following screen displays.

5. Use the up or down arrow key to select “1” to turn on parity checking or “0” to turn off parity

checking, then press [ENTER]. The SCSI Parity Option screen shows the new setting.

6. If desired, press [ESCAPE] to return to the SCSI Menu.

Setting the Clean Slot Option

The Clean Slot option designates the right-most fixed cartridge slot (closest to the tape drive) as a
permanent storage location for a cleaning cartridge.

To set the Clean Slot option:

1. If the security option is enabled, disable it.

2. Change the control mode to LCD (see page 66).

3. Display the Config Menu. If necessary, press [MENU] to display the menus. Press the down

arrow key until “Config Menu” displays, then press [ENTER]. The Baud Rate menu appears.

4. Press the down arrow key to display “Clean Slot Option,” then press [ENTER]. The Clean Slot

Option screen shows which slot is designated as the cleaning slot (15 in the example below)
and whether the option is on (1) or off (0).

5. Press [ENTER]. The following screen appears.

6. Press the up or down arrow key to select “1” to turn the fixed cleaning slot option on or “0” to

turn it off, then press [ENTER]. The Clean Slot screen shows the current selection.



S C S I

P a r i t y

O p t i o n

:

1

S C S I

P a r i t y

?

1



C l e a n

S l o t

( 1 5 )

O p t i o n :

0

C l e a n i n g

S l o t

a t

S l o t

1 5 ?

0

Advertising