Setting the autoclean option – Plasmon V15 User Manual

Page 44

Advertising
background image

Plasmon

V

15 AIT Tape Library User Manual

Page 42

Setting the Autoclean Option

The Autoclean option allows the library to automatically perform the cleaning process without interrupting
normal library operation. With Autoclean enabled, the library monitors the cleaning requirements of the
tape drive. When the drive indicates a “Needs Cleaning” status, the robot automatically removes the
cleaning cartridge from the cleaning cartridge slot and inserts it into the tape drive. After completing the
cleaning cycle, the library decreases the Clean Cycles Left counter by one.

NOTE

If you enable Autoclean, make sure the cleaning option in your
software is turned off.

To set the Autoclean option:

1. If the security option is enabled, disable it.

2. Display the Config Menu. If necessary, press [MENU] to display the menus. Press the down

arrow key until “Config Menu” displays, then press [ENTER].

3. Press the down arrow key until “Autoclean Option” displays. This screen shows whether

Autoclean is enabled (1) or not (0).

NOTE

To use Autoclean, the clean slot must contain a cleaning cartridge and
the Clean Slot option must be enabled.

4. Press [ENTER]. The following screen displays.

5. Press the up or down arrow key to select “1,” which turns on the Autoclean option, or “0” to

turn the option off, then press [ENTER].

NOTE

When the library’s Clean Cycles Left counter reaches zero, the library
disables Autoclean and displays a message on the status screen
reminding you to replace the cleaning tape.



A u t o c l e a n

O p t i o n :

0

A u t o c l e a n

D r i v e

?

0