Base Module

855-900547-200 2-68

(For 32Way(B))
---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 ---
XBX_C0(loc=M-14/23) ONLINE enable DEG

XBX00 (loc=M-14/23) ONLINE enable DEG

CXI port00 ONLINE enable --- --->CELL0 CXI_P0

CXI port01 offline DISABLE* --- --->CELL1 CXI_P0
CXI port02 ONLINE enable --- --->CELL2 CXI_P0
CXI port03 offline DISABLE* --- --->CELL3 CXI_P0
IB_CABLE port04 ONLINE enable --- --->PCIBAY0_P0

IB_CABLE port05 ONLINE enable --- --->PCIBAY2_P0

XXI port06 ONLINE enable --- --->XBX_C2_P06
XXI port07 offline DISABLE* --- --->XBX_C2_P07

XBX01 (loc=M-14/23) ONLINE enable DEG

CXI port10 ONLINE enable --- --->CELL0 CXI_P1
CXI port11 offline DISABLE* --- --->CELL1 CXI_P1
CXI port12 ONLINE enable --- --->CELL2 CXI_P1
CXI port13 offline DISABLE* --- --->CELL3 CXI_P1
IB_CABLE port14 ONLINE enable --- --->PCIBAY1_P0

IB_CABLE port15 ONLINE enable --- --->PCIBAY3_P0

XXI port16 ONLINE enable --- --->XBX_C2_P16
XXI port17 offline DISABLE* --- --->XBX_C2_P17

(j)

(For 32Way(H))
---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 ---
XBX_C0(loc=M-14/23) ONLINE enable DEG

XBX00 (loc=M-14/23) ONLINE enable DEG

CXI port00 ONLINE enable --- --->CELL0 CXI_P00

CXI port01 offline DISABLE* --- --->CELL0 CXI_P10

CXI port02 ONLINE enable --- --->CELL2 CXI_P00
CXI port03 offline DISABLE* --- --->CELL2 CXI_P10
IB_CABLE port04 ONLINE enable --- --->PCIBAY0_P0

IB_CABLE port05 ONLINE enable --- --->PCIBAY2_P0

XXI port06 ONLINE enable --- --->XBX_C2_P06
XXI port07 offline DISABLE* --- --->XBX_C2_P17
XXI port08 offline DISABLE* --- --->XBX_C0_P18

XBX01 (loc=M-14/23) ONLINE enable DEG

CXI port10 ONLINE enable --- --->CELL1 CXI_P00
CXI port11 offline DISABLE* --- --->CELL1 CXI_P10
CXI port12 ONLINE enable --- --->CELL3 CXI_P00
CXI port13 offline DISABLE* --- --->CELL3 CXI_P10
IB_CABLE port14 ONLINE enable --- --->PCIBAY1_P0

IB_CABLE port15 ONLINE enable --- --->PCIBAY3_P0

XXI port16 ONLINE enable --- --->XBX_C2_P16
XXI port17 offline DISABLE* --- --->XBX_C2_P07
XXI port18 offline enable --- --->XBX_C0_P08

(j)

The XBX is non-existent on the 8Way.

(For ISPF)
---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 ---
XBX_C0(loc=M-00/10) ONLINE enable DEG

XBX00 (loc=M-00/10) ONLINE enable DEG

CXI port00 ONLINE enable --- --->CELL0 CXI_P1
CXI port01 offline DISABLE* --- --->CELL1 CXI_P1
IB_CABLE port04 ONLINE enable --- --->SYS1 XBX_C0_P04

IB_CABLE port05 ONLINE enable --- --->SYS1 XBX_C0_P05