En (environmental information) – NEC NX7700i/5040H-32 User Manual

Page 77

Advertising
background image

Base Module

855-900547-200

2-41

2.4.6.5.

EN (Environmental Information)

m b u

X

* Always valid without regard to the current system status.

Function:

This command is used to list system environmental data including temperature sensor data,
FAN error, and so on.

Note that part of the environmental monitoring functions are not available to inactive
components.

The temperature sensor threshold shown in the following Screen Example may not reflect the
actual threshold.

(Screen Example)

Description

No.

iSPyz:--->

en

<ENTER>

select display mode? (i[nteractive per page]/a[ll]/CR=exit) :

i

<ENTER>

(a)

(32Way: For one or two AC power receiving systems)
---- Power Bay Units ------------------------------- 19:20:57,01/31/2005 ----
state DPS0 DPS1 DPS2 DPS3 DPS4 DPS5
* MAIN POWBAY0 ON --- --- ALARM ---
* POWBAY1 ON --- --- NORESP ---
EXT POWBAY2 OFF --- --- --- ---
POWBAY3 OFF --- --- --- ---
-----------------------------------------------------------------------------

(8Way/ISPF: For one or two AC power receiving systems)
---- Power Bay Units ------------------------------- 19:20:57,01/31/2005 ----
state DPS0 DPS1 DPS2 DPS3 DPS4 DPS5
* MAIN POWBAY0 ON --- --- ALARM --- --- ---
* EXT POWBAY1 ON --- NORESP ---
-----------------------------------------------------------------------------
ISPF does not have two AC power receiving systems.

(8Way/ISPF receiving 48 VDC)
---- Power Bay Units ------------------------------- 19:20:57,01/31/2005 ----
state

EXT POWBAY1 ON

(b)