Tone Enable Check Box

The Tone Enable check box indicates whether or not the function tone is active. If selected, the function tone is active. The
frequency for the tone is set on the Tone Frequency and Durations window described on page 112. The standard function tones
and their frequencies are the default entries. These entries are shown in Table 7 on page 114.

NOTE:

At least one function tone must be selected.

Relay Drop Down Menu

The Relay drop down menu, shown in Figure 98, identifies the relay(s), if any, closed immediately upon receipt of the
function tone.

Available selections for this field are: no selection, R01, R02, or BOTH.

Relay Group Drop Down Menu

The Relay Group drop down menu identifies if a relay is grouped into separate functions. This allows more than one relay to
be activated at any particular time by being in separate groups. For example, when F1 has R1 selected as its relay, and F2 has
R2 selected as its relay, setting the two Relay Group numbers to the same value allows multiple relays with different functions.
In this scenario, the relays for F1 and F2 are interlocked. When the Relay Group assigned to F1 and F2 are different, R2 does
not activate when F1 is received. Furthermore, when there is no relay selected for a function tone, but the assigned relay group
is used by another relay group, when the function tone is received, all relays in the group are activated. This allows relay R1
and R2 to be assigned to different groups and use other function tones within the same relay group to activate them.

Select either 1 or 2 from the drop down menu.

Relay Time (ms) Field

The Relay Time (ms) field identifies if the selected relay(s) latch ON when the function tone is received, or if the selected
relay(s) is latched ON for a specified period of time when the function tone is received. To program the relay(s) to latch ON
when the function tone is received enter a zero (0) in the field. To set the duration the relay(s) is latched ON, enter the desired
amount of time, in ms, in the field.

The range for this field is 0 to 32000.

FIGURE 98.