Configuration

Standard Control Panel Parameters

1/7/10

Xi4™/RXi4™ User Guide

P1009874-002

Set Host Handshake
This setting applies only when the serial port is used. The handshake
protocol of the printer must match the handshake protocol of the host
computer for communication to take place. Select the handshake protocol
that matches the one being used by the host computer.

Default Value: XON/XOFF

Selections: XON/XOFF, DSR/DTR, RTS/CTS

To change the value shown:

1.

Press

PLUS (+)

or

MINUS (-)

to scroll through the options.

Set Protocol
Protocol is a type of error checking system. Depending on the selection, an
indicator may be sent from the printer to the host computer signifying that
data has been received. Select the protocol that is requested by the host
computer. Further details on protocol can be found in the Programming
Guide for ZPL, ZBI, Set-Get-Do, Mirror, and WML
.

Default Value: NONE

Selections: NONE, ZEBRA, ACK_NAK

Note •

ZEBRA

is the same as

ACK_NAK

, except that

ZEBRA

response messages are sequenced. If

ZEBRA

is selected, the printer

must use

DSR/DTR

for host handshake protocol.

To change the value shown:

1.

Press

PLUS (+)

or

MINUS (-)

to scroll through the options.

Set Network ID
This parameter assigns a unique number to the printer when the printer is
operating in an RS422/485 multi-drop network environment (an external
RS422/485 adapter is required). This gives the host computer the means to
address a specific printer. This does not affect TCP/IP or IPX networks.

Default Value: 000

Range: 000 to 999

To change the value shown:

1.

Press

MINUS (-)

to move to the next digit position.

2.

Press

PLUS (+)

to increase the value of the digit.

Set Communications Mode
The communication diagnostics mode is a troubleshooting tool for
checking the interconnection between the printer and the host computer.
For more information, see

Communications Diagnostics Test on page 160

.

Default Value: NORMAL MODE

Selections: NORMAL MODE, DIAGNOSTICS

To select communication diagnostics mode:

1.

Press

PLUS (+)

or

MINUS (-)

to toggle between the options.

Table 8 • Printer Parameters (Sheet 13 of 22)