Zebra Technologies ZEBRA RXI4TM User Manual

Page 104

Advertising
background image

Configuration
Standard Control Panel Parameters

104

P1009874-002

Xi4™/RXi4™ User Guide

1/7/10

Set Control Prefix Character
The printer looks for this two-digit hex character to indicate the start of a
ZPL/ZPL II control instruction.

Note •

Do not use the same hex value for the control, format, and

delimiter character. The printer must see different characters to
work properly.

Default Value: 7E ~

Range: 00 to FF

To change the value shown:

1.

Press

MINUS (-)

to move to the next digit position.

2.

Press

PLUS (+)

to increase the value of the digit.

Set Format Prefix Character
The format prefix is a two-digit hex value used as a parameter place marker
in ZPL/ZPL II format instructions. The printer looks for this hex character
to indicate the start of a ZPL/ZPL II format instruction. See the
Programming Guide for ZPL, ZBI, Set-Get-Do, Mirror, and WML
for more
information.

Note •

Do not use the same hex value for the control, format, and

delimiter character. The printer must see different characters to
work properly.

Default Value: 5E ^

Range: 00 to FF

To change the value shown:

1.

Press

MINUS (-)

to move to the next digit position.

2.

Press

PLUS (+)

to increase the value of the digit.

Set Delimiter Character
The delimiter character is a two-digit hex value used as a parameter place
marker in ZPL/ZPL II format instructions. See the Programming Guide for
ZPL, ZBI, Set-Get-Do, Mirror, and WML
for more information.

Note •

Do not use the same hex value for the control, format, and

delimiter character. The printer must see different characters to
work properly.

Default Value: 2C ,

Range: 00 to FF

To change the value shown:

1.

Press

MINUS (-)

to move to the next digit position.

2.

Press

PLUS (+)

to increase the value of the digit.

Table 8 • Printer Parameters (Sheet 14 of 22)