131

Routine Maintenance

Replace the Fuse

1/7/10

Xi4™/RXi4™ User Guide

P1009874-002

Replace the Fuse

The instructions that follow are for the 140Xi4, 170Xi4, and 220Xi4 printers only. Fuses are
not user-replaceable in the 110Xi4.

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is
provided as a spare. The end caps of the fuse must bear the certification mark of a known
international safety organization (see

Figure 5 on page 29

).

To replace a faulty fuse, complete these steps:

1.

2.

Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer (

Figure 21

).

Figure 21 • AC Power Entry Module

3.

Remove the faulty fuse and install a new fuse in the in-circuit position (

Figure 22

).

Caution • Turn the AC power switch off (O) and remove the power cord before performing
this procedure.

Caution • Turn off (O) the printer and disconnect it from the power source before
performing the following procedure.

Turn off (

O

) the printer, and disconnect the AC power cord and all data cables.

1

Power switch

2

Fuse holder

3

AC power entry module

4

Small-blade screwdriver

Important •

If you use the spare fuse, be sure to order a replacement fuse from an

authorized Zebra distributor. The spare fuse should be the exact type and rating as the
original in-circuit fuse.

1

2

3

4

Advertising