VEGA VEGAPULS 45 VBUS User Manual
Page 45
VEGAPULS 42, 44 and 45 – VBUS
45
Adjustment with the PC on the signal conditioning instrument
The adjustment program VEGA Visual Oper-
ating (VVO), called in the following VVO, gets
into contact with the connected sensor or
processing system …
… and indicates after a few seconds if and
with which system a connection exists.
Note:
If you make no connection with the sensor,
check the following:
- Is the sensor being supplied with sufficient
voltage (min. 20 V)
?
- Did you inadvertently use a
VEGACONNECT instead of the new
VEGACONNECT 2?
If the adjustment software VVO gets in con-
tact with the signal conditioning instrument for
the first time, you will be asked if you want to
transfer the data from the signal conditioning
instrument to the PC.
• Click to "
Yes".
In the following menu window "
DISBUS-group
choice" you can give a name to the database
or keep the proposed file name.
• Click to "
OK" and you are in the main menu
window.
User identification
The preset user identification can be modified
later in the menu "
User access".