VEGAPULS 42, 44 and 45 – VBUS

• Confirm your adjustments with "

OK".

Adjustment with the PC on VEGALOG

The menu window "

Create new measurement

loop - Measurement loop designation" opens.

Enter:
- a measurement loop number
- a measurement loop description
- allocate one or several output signals to

your sensor.

• For example, configure a current output by

clicking to "

Current output".

In the menu window "

Configure current out-

put", you choose a current output card in
your VEGALOG and allocate one or several
current outputs to the sensor.

• Confirm your adjustment with "

OK" and you

are again in the window "

Create new meas-

urement loop - Measurement loop designa-
tion".

• Click to "

Quit" and you are again in the

initial menu.

You have carried out the special additional
configuration settings in conjunction with a
VEGALOG.

In the menu "

Configuration/Measuring sys-

tem" you now see that one sensor is
configured.