VEGAPULS 42, 44 and 45 – VBUS

49

In the opening menu window, you now see
the previously entered measurement loop
names and the measurement loop descrip-
tions.

• First choose

"Adjustment".

• Click in the menu window "

Adjustment" to

"Min/Max adjustment".

You can carry out the min./max. adjustment
"with medium" (adjustment by means of the
actual level) or

"without medium" (without

taking the actual level into consideration, i.e.
with empty vessel).

Generally, you will carry out the adjustment
without medium, inasmuch as you need not
be concerned about the actual vessel filling
during adjustment. If you want to carry out
the adjustment with medium, you have to
carry out the min. adjustment with emptied
(also partly emptied) vessel and the max.
adjustment with filled (also partly filled) ves-
sel. Carrying out the adjustment without me-
dium is more convenient and quicker, as
shown in the example.

• Choose "

no (adjustment without medium)".

• Choose if you want the carry out the ad-

justment in

meters (m) or in feet (ft).

• Enter a distance for the upper and lower

level and the volume in % corresponding to
each distance.

Adjustment with the PC on the signal conditioning instrument

Parameter adjustment 1

In the menu "

Instrument data/Parameter ad-

justment" you carry out all important sensor
adjustments.

Adjustment

• Choose the menu "

Instrument data/Para-

meter adjustment" and then the sensor you
want to adjust.

If you have only configured one sensor on
the signal conditioning instrument, you will of
course have a choice of only one sensor.