Trapezoidal weir (Cipolletti)

With sharp overflow edge

Values for Q

max

B

K

Q

max

h

max

Q

min

h

min

in mm

(Factor)

in m

3

/h in mm

in m

3

/h in mm

300

2011

116,8

150

29,5

60

450

3014

354,4

240

44,3

60

600

4011

760,4

330

58,9

60

800

5353

1457

420

78,7

60

1000

6688

2581

530

93,3

60

1500

10043

6523

750

147,6

60

2000

13381

14397

1050

196,7

60

3000

20082

36893

1500

295,1

60

Calculation of Q

max

The following formula can be used for calculation of
the actual flow of liquid levels < h

max

… h

min

.

Presumed values for a calculation example
B = 0,6 m
K = 4011 (derived from B)
h = 0,27 m

Q

max

= K x h

1,5

= 4011 x 0,27

1,5

= 562,73 m

3

/h

Rectangular overflow without contraction

With sharp overflow edge without throat

Values for Q

max

B

Q

max

h

max

Q

min

h

min

in mm

in m

3

/h

in mm

in m

3

/h in mm

200

54,81

120

19,4

60

400

310

240

38,7

60

600

650

300

58,1

60

800

1592

450

77,5

60

1000

3064

600

96,9

60

1500

6423

750

145,3

60

Calculation of Q

max

The following formula can be used for calculation of
the actual flow of liquid levels < h

max

… h

min

.

Presumed values for a calculation example
B = 1,5 m

K = 6593
h = 0,3 m

Q

max

= B x K x h

1,5

= 1,5 x 6593 x 0,3

1,5

= 1625 m

3

/h

B

h

max

1

/

4

h

max

B

h

max

K = 6593

>>

Advertising