VEGAMET 514… D

31

Rectangular overflow without contraction

With sharp overflow edge and throat

Set-up, parameter adjustment

Values for Q

max

B

Q

max

h

max

Q

min

h

min

in mm

in m

3

/h

in mm

in m

3

/h in mm

200

52,3

120

18,5

60

300

109,6

150

27,7

60

400

295,8

240

37,0

60

500

441,2

270

46,2

60

600

620

300

55,5

60

800

1519

450

73,9

60

1000

2923

600

92,4

60

1500

6128

750

138,7

60

2000

13535

1050

184,9

60

3000

34666

1500

277,3

60

Calculation of Q

max

The following formula can be used for calculation of

the actual flow of liquid levels < h

max

… h

min

.

Presumed values for a calculation example
B = 0,4 m
K = 6290

h = 0,13 m

Q

max

= B x K x h

1,5

= 0,4 x 6290 x 0,13

1,5

= 117,9 m

3

/h

Rectangular flume (V-Notch)

With sharp overflow edge

Values for Q

max

α

K

Q

max

h

max

Q

min

h

min

in

°

(Factor)

in m

3

/h in mm

in m

3

/h in mm

90

4966

1385,0 600

4,4

60

60

2869

800,0

600

2,5

60

45

2056

573,3

600

1,8

60

30

1334

372,0

600

1,2

60

22,5

989

275,8

600

0,87

60

Calculation of Q

max

The following formula can be used for calculation of
the actual flow of liquid levels < h

max

… h

min

.

Presumed values for a calculation example

α

= 45

°

K = 2056 (derived from

α

)

h = 0,33 m

Q

max

= K x h

2,5

= 2056 x 0,33

2,5

= 128,6 m

3

/h

B

h

max

K = 6290

h

max

α

>>

Advertising