32
VEGAMET 514… D
Set-up, parameter adjustment
Palmer-Bowlus-Flume
Values for Q
max
D
K
Q
max
h
max
Q
min
h
min
in Zoll
(Factor)
in m
3
/h in mm
in m
3
/h in mm
6"
1952
37,82
120
2,9
30
8"
2338
68,60
150
7,3
45
10"
2712
148,8
210
12,3
55
12"
3046
214,3
240
18,9
65
15"
3519
374,8
300
32,1
80
18"
3943
501,4
330
54,4
100
24"
4745
1074,0 450
114,5
135
30"
5488
2122,0 600
192,3
165
Note:
The data of above schedule relate to Palmer-Bowlus-
Flumes of Messrs. Plasti-Fab.
Calculation of Q
max
The following formula can be used for calculation of
the actual flow of liquid levels < h
max
… h
min
.
Presumed values for a calculation example
D = 12"
K = 3046 (derived from D 12")
h = 0,2 m
Q
max
= K x h
1,86
= 3046 x 0,2
1,86
= 152,63 m
3
/h
h
max
D
/
6
D
/
4
D
/
2
D
/
4
D
/
2
D
30
°
30
°
Advertising