Buj terminal connection board, Connection board, S1.2: software mode – GE Industrial Solutions Galaxy Vector Rack Mounted Controller J85501M-1 User Manual

Page 21

Advertising
background image

Galaxy Rack-Mounted Vector Controller J85501M-1

Issue 2 January 2008

Product Description 2 - 7

BUJ Terminal
Connection
Board

Figure 2-6 shows the BUJ Terminal Connection Board. The
following pages describe the required connections. Note: To
make connections to the 1U_ALM Board terminal blocks, pull
the front of the insulating cover off of the mounting posts.

Figure 2-6: J85501M-1 Vector Controller / BUJ Terminal Connection Board

HDR3

HDR1

HDR2

J4

S1

FH1

P2

J6

J9

P5

J5

-

+

-

+

J13

J14

1

J21

1

J1

5

1

1

1

J1

9

1

J18

J2

0

J17

J16

BUZ1

J7

J8

J3

J1

2

2

8

1

1

8

A1

B1

C1

A32

C32

1

1

1

1

1

1

2

3

4

5

6

7

8

1

0

TERM RES

RS485

POWER

OPT

RS

232

1 1/3A

ABS FUSE

AMJ

FAJ

LV

D

1

LV

D

2

THE

RM 2

THE

RM 1

FOR

CE ON

AUTO

FOR

CE ON

24V

48V

48V

24V

24V

48V

24V

48V

ON

OFF

LOCAL RS232

KE

Y PAD

DISP

LAY

R10

BUJ Board

GCM Board

Keypad

Display

Display Contrast Control
Potentiometer

J7,J8: RS-485 to Rectifiers

J5: BSM3/BSM4 Modem

or EBW1 Ethernet Board

P2: Alarm Board

J15,J20: LVD Force-On Jumpers

J11,J12,J18,J19:
24V / 48V Selection Jumpers

J21: Manual Buzzer

Disable Jumper

J4: Local RS-232 DB9 Port

S1: DIP Switch

ABS Fuse

P5: Power

Shunt
Vsense

J16: AMJ Input

J17: FAJ Input

J13: LVD1

J14: LVD2

J1: Thermal Probe 1

or 210E

J3: Thermal Probe 2

or 210E

System Voltage and
Shunt Test Points

S1.2: Software Mode

1,2

S1.3: Option Card Availability

S1.1: Front Panel Configuration

0
1

0
1

0
1

- Enabled (shown)
- Disabled

- Standard (shown)
- Custom Default Configuration Parameters

3

- Modem
- Galaxy Gateway Card (Internet)

S1.4: Rectifier Class

0
1

- Standard GPS Rectifiers
- NP/AC3000 Rectifiers

S1.5: Alarm Contact Select

1

S1 DIP Switch Settings

S1.7: Plant Battery Test

0
1

0
1

0
1

- Standard HV, High Voltage
- VLV, Very Low Voltage

- Disabled (shown)
- Active

- Normal (shown)
- Reset Display

S1.6: - Set to 0

S1.8: - Display Reset

4

1. Setting both SW1.2 and SW1.5 to "1" will result in activating the HV alarm cont act.
2. SW1.2 setting will only be read by the software when the GCM is powered up.
3. HV alarm contacts used for 2ACF alarm instead of HV alarm.
4. Cycling from "0" to "1" and back to "0" will reset the display.

S1

8
7
6
5
4
3
2
1

0

1

TJ2

TJ1

RED/ROJO

BLK/NEGRO

PLAN

T

V

SH

U

N

T

Advertising