—————— Digital General Function Card ——————

6KCV301DGF

parameter are saved in the DBASE_FLASH, while the
parameter value won’t be saved. This means that when the DGF
is reset, the DEFAULT value of this parameter contained in the
DBASE_ROM is loaded, while the attributes record is loaded
from DBASE_FLASH. The utility of this option is when, for
instance, with a read-only parameter, the user wants to change
the attribute NAME or the attribute UNM. This operation can
be executed only when the DGF is in status of IDLE.

IDLE

This option indicates that the parameter and respective attributes

are stored in the DBASE_FLASH. This operation can be carried
out only when the DGF is in IDLE status.

RUN

This option indicates that the parameter is stored in
DBASE_EEPROM in each status, while the attributes will be
stored in the DBASE_FLASH only in IDLE status.

The commands that allow the execution of the above-mentioned operations are described
in Appendix A. Key-pad operation is described in section 2.4.1.