3 data formats – GE Industrial Solutions 6KCV301DGF User Manual

Page 37

Advertising
background image

37

—————— Digital General Function Card ——————

6KCV301DGF

EXCEPTION

ID

NAME

LEDs H4-H3-

H2-H1

(1 = ON, 0 =

OFF)

BRIEF DESCRIPTION

1

80387

0-0-0-1

severe hardware error (*)

2

divide error

0-0-1-0

division by 0/division overflow

(**)

4

INT0 detected
overflow

0-1-0-0

5

array bound

0-1-0-1

6

invalid opcode

0-1-1-0

7

coprocessor not
available

0-1-1-1

severe hardware error (*)

8

double fault

1-0-0-0

9

coprocessor
segment overrun

1-0-0-1

10

invalid Tss

1-0-1-0

11

segment not
present

1-0-1-1

12

stack exception

1-1-0-0

13

general protection

1-1-0-1

14

page fault

1-1-1-0

15

bus failure

1-1-1-1

severe hardware error (*)

d0210g

severe software error (*)

severe software error (*)

(*) :

Replace DGF or Regulation card. If the problem persist please contact your

sales office.

(**):

Verify application,check the scheme or parameter for Mathematical error (E.g.
division by 0).

Advertising