7 how to configure the dgf – GE Industrial Solutions 6KCV301DGF User Manual
Page 56
—————— Digital General Function Card ——————
56
GEI-100430
When the period is activated by the drive(PERIOD_MODE=1) this
parameter indicates the number of times that the synchronous period
takes longer than PERIOD_TIM. This parameter must be always 0.
[510]
SBORD ASYN
Number of times the period exceeds
PERIOD_TIM
When the period is activated by the DGF(PERIOD_MODE=2) this
parameter indicates the number of times that the asynchronous period
takes longer than PERIOD_TIM. This parameter must be always 0.
[511]
ADDRESS
Address of the card for SLINK 3
It is used to write the Slink3 address of the DGF. If written, the value
is copied and saved in parameter [3] “ACT-ADDR”.
Note: the address of the serial line cannot be saved in a parameter
file.
[512]
Real time
Maximum real period time
This is the maximum number of milliseconds taken by the user
program to execute the period.
[555]
CMD_REMOTE Remote command
It allows the receiving of DBASE commands via the serial line of
the drive or via a communication card. Possible commands:
CODE
COMMAND
310
Save Dbase parameters
311
Load Dbase parameters
312
Check Dbase parameters
313
Init. Dbase parameters
d0350g