1 alarm code from the drive, 2 severe alarm, Table 2.2.2.7: alarm code 22 (al_dnet) cause – GE Industrial Solutions 6KCV301DGF User Manual

Page 36

Advertising
background image

—————— Digital General Function Card ——————

36

GEI-100430

CAUSE

NAME

DESCRIPTION

0..1000

ALC_WFIX

WFIX brick alarm

1000..1999 ALC_RFIX

RFIX brick alarm

2000..3999 ALC_CFIX

CFIX brick alarm

10000

ALC_M10_TIMEOUT

Time-out mode 10

d0180g

Table 2.2.2.7: Alarm code 22 (AL_DNET) cause

2.2.2.1 Alarm code from the drive
The following ALARM CODES are generated by the drive if it detects a malfunction
with the DGF.

Replace DGF or Regulation card, check XO connections

CODE

NAME

TYPE

DESCRIPTION

100 AL_DPRAM_DRV

1

DPRAM communications on Drive

101 AL_CCZ_DRV

2

CCZ hardware on drive

d0190g

Alarm 100 (AL_DPRAM_DRV): ALARM CAUSES

CAUSE

NAME

DESCRIPTION

1

AL_WD_SW

Software watchdog on drive

2

AL_CHK_KEY

Checksum err. on keypad communication

3

AL_CFG_OPAZ_LP

Configuration err. IE-ASYN

4

AL_CHK_OPAZ_LP

Checksum err. IE-ASYN

5

AL_CFG_OPAZ_HP

Configuration err. IE-SYN

6

AL_SEM_OPAZ_HP

Semaphore IE-SYN

7

AL_LWR_OPAZ_HP

Last write IE-SYN

8

AL_CHK_OPAZ_HP

Checksum IE-SYN

9

AL_CFG_AZOP_LP

Configuration EI-ASYN

10

AL_CFG_AZOP_HP

Configuration EI-SYN

11

AL_SEM_AZOP_HP

Semaphore EI-SYN

12

AL_LWR_AZOP_HP

Last write EI-SYN

13

AL_SYNC_WD

Watch dog synchronization alarm

99

AL_GEN_DPRAM

Drive DPRAM structure has been
disabled

111

OPT2_TMO_SINCRO

Synchronization timeout

d0200g

2.2.2.2 Severe alarm
It is not always possible for the DGFCy to recover from an unexpected condition. In
this case all functionality of the card is disabled. The DGFCy starts blinking LEDs
H1,H2,H3 and H4. The following table describes the type of these errors. The exception
ID is the number that is blinked on the LEDs.