3 i/o configuration, 4 mode configuration, 5 can controller parameters (devicenet) – GE Industrial Solutions 6KCV301DGF User Manual

Page 53: 6 system parameters

Advertising
background image

53

—————— Digital General Function Card ——————

6KCV301DGF

[299]

EN DPRAM

Disables the DPRAM communication structure
when it is equal to “0”.

If it is changed, it has an effect only after a hardware reset.

2.6.2.3 I/O configuration
[300]

CW_CPU

Control word of CPU

Enables the use of some hardware resources of the DGF

[301, 303, 305, 307] ID_CARD

Cards 1, 2, 3, 4 identifier

Identifies the DGF I/O optional card used (not yet available)

[302, 304, 306, 308] CW_CARD

Control word card 1, 2, 3, 4

Each card has a control word associated (not yet available)

2.6.2.4 Mode configuration
[350]

DGF_MODE

It sets the mode of the DGF

Permissible values are the following:

0 =

Only BRICKS Enabled

1 =

BRICKS and WIN+DRIVE Enabled

2 =

Only WIN+DRIVE Enabled

10 =

Only DeviceNet enabled

[351]

WPD STATUS

Status of WIN+DRIVE block

Permissible values are the following:

0 =

WIN+DRIVE block disabled

1 =

WIN+DRIVE block enabled

2.6.2.5 Can controller parameters (DeviceNet)
The range of indexes of the parameters dedicated to DeviceNet is from 400 to 499.

For a detailed description, see DeviceNet manual.

2.6.2.6 System parameters
These are parameters that modify the behavior of the system, e.g.. on sampling period
or status logic and define the various modes at which the operation status of the option
can be changed.

[500]

PERIOD_MODE Working operation mode; possible values are:

1 =

synchronous with drive

2 =

asynchronous (DGF internal Timer)

Any other value can crash the DGF .

Advertising