2 reading the meter display – E-Mon E-D5-600800-S*SPL3-V3KIT3 User Manual

Page 50

Advertising
background image

DIN-MON™ SMART METER

62-0442—04

50

8.2 Reading the Meter Display

The Din-Mon

TM

meter features seven different screens showing monitoring data. Each

screen is displayed for 5 second intervals, before scrolling onto the next screen.

You can “lock” the scrolling display on any one of the seven screens. This will be

explained in detail on following pages. Explanations of these displays are as follows:

NOTE: Not all items will be shown on 1-phase or 2-phase models.

Screen

Description

Display

1

Total Kilowatt-Hours (kWh) Consumed

(Delivered)

2

Peak Demand (kW)

with Date and Time Stamp

3

Present Load (kW)

with Present Date and Time

4

Current (Amps) Per Phase

5

Voltage (Volts)

Phase to Neutral (for WYE service)

6

Voltage (Volts) Phase to Phase

7

Power Factor (PF) Per Phase

TOTAL:

123 KWH

PEAK

25.5 KW

DATE

05/15

TIME

11:45

LOAD

24.0 KW

DATE

06/14/11

TIME

08:46:58

PH-A

119.8 V

PH-B

120.2 V

PH-C

119.5 V

PH-A

12.3 AMP

PH-B

10.2 AMP

PH-C

14.7 AMP

PH-AB

208.0 V

PH-BC

208.2 V

PH-CA

207.0 V

PH-A

97.4 % PF

PH-B

98.2 % PF

PH-C

98.6 % PF