AXF Standard, AXF015-AXF125, Sanitary for Clamp Connection, PFA Lining

28(1.1)

51.5

51.5

(2.03) (2.03)

Hr

H1

48

(1.89)

70(2.76)

111(4.37)

154(6.06)

Hi

Ground Terminal

(M4)

(M4)

Ground Terminal

ø86(3.38)

L

197(7.76)*

1

66*

1

ø

128(5.04)

Adapter for clamp connection

øD

(ød)

Adapter for clamp connection

(2.6)

F34.EPS

Integral Flowmeter

Remote Flowtube

Integral Flowmeter Remote Flowtube

Unit : mm (approx. inch)

73

(2.87)

49

(1.93)

*1: When indicator code N is selected, subtract 12 mm

(0.47 inch) from the value in the figure.

*2: When option code DHC is selected, waterproof

glands and a 30m long cable are attached.
Add 9.5kg(20.9lb) to the weight in the table.

ø

A

ø

B

ø

d

ø

E

ø

F

ø

C

G

Process

Connection

HAB (Tri–Clamp)

Nominal

Size

25

70

(2.76)

22.2

(0.87)

25.4

(1.00)

22.1

(0.87)

43.6

(1.72)

50.4

(1.98)

50

(1.97)

F9811

HV

15

70

(2.76)

16

(0.63)

19.2

(0.76)

15.7

(0.62)

25

(0.98)

50

(1.97)

F9811

HU

40

83

(3.27)

34.6

(1.36)

38.1

(1.50)

34.8

(1.37)

43.6

(1.72)

50.4

(1.98)

50

(1.97)

F9811

HX

50

96

(3.78)

47.6

(1.87)

50.8

(2.00)

47.5

(1.87)

56.3

(2.22)

64

(2.52)

50

(1.97)

F9811

HY

65

114

(4.49)

59.5

(2.34)

63.5

(2.50)

60.2

(2.37)

70.6

(2.78)

77.4

(3.05)

50

(1.97)

F9811

HZ

80

126

(4.96)

72.3

(2.85)

76.2

(3.00)

72.9

(2.87)

83.3

(3.28)

91

(3.58)

50

(1.97)

F9811

JA

100

152

(5.98)

97

(3.82)

101.6

(4.00)

97.4

(3.83)

110.3

(4.34)

118.9

(4.68)

50

(1.97)

F9811

JB

øA

øB

øC

ød

øE

øF

G

Parts No.

HDB (DIN 32676 Clamp)

15

70

(2.76)

16

(0.63)

20

(0.79)

16

(0.63)

27.5

(1.08)

34

(1.34)

50

(1.97)

F9811

JD

25

70

(2.76)

22.2

(0.87)

30

(1.18)

26

(1.02)

43.5

(1.71)

50.5

(1.99)

50

(1.97)

F9811

JE

32

70

(2.76)

29.4

(1.16)

36

(1.42)

32

(1.26)

43.5

(1.71)

50.5

(1.99)

50

(1.97)

F9811

JF

40

83

(3.27)

34.6

(1.36)

42

(1.65)

38

(1.50)

43.5

(1.71)

50.5

(1.99)

50

(1.97)

F9811

JG

50

96

(3.78)

47.6

(1.87)

54

(2.13)

50

(1.97)

56.5

(2.22)

64

(2.52)

50

(1.97)

F9811

JH

65

114

(4.49)

59.5

(2.34)

70

(2.76)

66

(2.60)

83.5

(3.29)

91

(3.58)

50

(1.97)

F9811

JJ

80

126

(4.96)

72.3

(2.85)

85

(3.35)

81

(3.19)

97

(3.82)

106

(4.17)

50

(1.97)

F9811

JK

100

152

(5.98)

97

(3.82)

104

(4.09)

100

(3.94)

110

(4.33)

119

(4.69)

50

(1.97)

F9811

JL

125

180

(7.09)

123

(4.84)

129

(5.08)

125

(4.92)

146

(5.75)

155

(6.10)

60

(2.36)

F9811

JM

HKB (ISO2852 Clamp)

15

70

(2.76)

16

(0.63)

18

(0.71)

15.2

(0.60)

27.5

(1.08)

34

(1.34)

50

(1.97)

F9811

JN

25

70

(2.76)

22.2

(0.87)

25.6

(1.01)

22.6

(0.89)

43.5

(1.71)

50.5

(1.99)

50

(1.97)

F9811

JP

32

70

(2.76)

29.4

(1.16)

34.3

(1.35)

31.3

(1.23)

43.5

(1.71)

50.5

(1.99)

50

(1.97)

F9811

JQ

40

83

(3.27)

34.6

(1.36)

38.6

(1.52)

35.6

(1.40)

43.5

(1.71)

50.5

(1.99)

50

(1.97)

F9811

JR

50

96

(3.78)

47.6

(1.87)

51.6

(2.03)

48.6

(1.91)

56.5

(2.22)

64

(2.52)

50

(1.97)

F9811

JS

65

114

(4.49)

59.5

(2.34)

64.1

(2.52)

60.3

(2.37)

70.5

(2.78)

77.5

(3.05)

50

(1.97)

F9811

JT

80

126

(4.96)

72.3

(2.85)

76.7

(3.02)

72.9

(2.87)

83.5

(3.29)

91

(3.58)

50

(1.97)

F9811

JU

100

152

(5.98)

97

(3.82)

102.5

(4.04)

97.6

(3.84)

110

(4.33)

119

(4.69)

50

(1.97)

F9811

JV

125

180

(7.09)

123

(4.84)

141.2

(5.56)

135.7

(5.34)

146

(5.75)

155

(6.10)

60

(2.36)

F9811

JW

H

D
E

F

G
N

P

1
2

N

A L 1 N

H
H
H

A
D
K

B
B
B

1

AXF015
AXF025
AXF032
AXF040
AXF050
AXF065
AXF080
AXF100
AXF125

*3: D, E, F, G; Integral Flowmeter,

N, P; Remote Flowtube

*3

Process Connection

HAB / HDB / HKB

Max. Height

Hr

Hi

Max. Height

Weight kg (lb)

Height

H1

Size code

Size

Lining code

Face-to-face

length

L

Outside dia.

Inner dia.

ø

D

ø

d

HDB

HKB

HAB

Model

Remote
Flowtube

Integral
Flowmeter

Remote
Flowtube

Integral
Flowmeter

015

15

(0.5)

A

166

(6.55)

73

(2.87)

15.7

(0.62)

16

(0.63)

15.2

(0.60)

98

(3.86)

222

(8.74)

2.7

(6.0)

260

(10.22)

4.4

(9.7)

025

25

(1)

A

166

(6.55)

73

(2.87)

22.1

(0.87)

26

(1.02)

22.6

(0.89)

98

(3.86)

222

(8.74)

2.5

(5.5)

260

(10.22)

4.2

(9.3)

032

32

(1.3)

A

166

(6.55)

73

(2.87)

32

(1.26)

31.3

(1.23)

98

(3.86)

222

(8.74)

2.6

(5.7)

260

(10.22)

4.3

(9.5)

040

40

(1.5)

A

166

(6.55)

86

(3.39)

34.8

(1.37)

38

(1.50)

35.6

(1.40)

111

(4.37)

235

(9.25)

2.9

(6.4)

273

(10.73)

4.6

(10.1)

050

50

(2)

A

176

(6.94)

99

(3.90)

47.5

(1.87)

50

(1.97)

48.6

(1.91)

129

(5.08)

253

(9.96)

3.6

(7.9)

291

(11.44)

5.3

(11.7)

065

65

(2.6)

A

196

(7.73)

117

(4.61)

60.2

(2.37)

66

(2.60)

60.3

(2.37)

147

(5.79)

271

(10.67)

4.8

(10.6)

309

(12.15)

6.5

(14.3)

080

80

(3)

A

216

(8.52)

129

(5.08)

72.9

(2.87)

81

(3.19)

72.9

(2.87)

157

(6.18)

281

(11.06)

5.7

(12.6)

319

(12.54)

7.4

(16.3)

100

100

(4)

A

246

(9.70)

155

(6.10)

97.4

(3.83)

100

(3.94)

97.6

(3.84)

183

(7.20)

307

(12.09)

8.1

(17.9)

345

(13.56)

9.8

(21.6)

125

125

(5)

A

316

(12.46)

183

(7.20)

125

(4.92)

135.7

(5.34)

212

(8.35)

336

(13.23)

12.1

(26.7)

374

(14.70)

13.8

(30.4)

*

2

Weight kg (lb)

* No infra-red switches are furnished
for Fieldbus communication type.

Advertising