Yokogawa ADMAG AXF User Manual

Page 93

Advertising
background image

IM 01E20D01-01E

6-31

6. OUTLINE

Table of Optional Specifications (Size 2.5 mm (0.1 in.) to 400 mm (16 in.)) (continued)

Code

Submersible

Sanitary

Applicable Model

General

Item

Specifications

X2

Epoxy Resin Coating

Epoxy resin coating which has alkali-resistance instead of standard

polyurethane resin coating. The color is same as standard type.

Material Certificate

High Anti-corrosion

Coating

Three-layer coating (polyurethane coating on two-layer epoxy resin

coating) in the same range as that for the standard coating. The color is

same as standard type. Salt/alkali/acid/weather-resistance.

Reproduced material certificates for :

PFA/polyurethane: Pipe, electrodes, grounding rings/grounding

electrodes, flanges or mini flanges, adapters (for sanitary type)

Ceramics: only grounding rings or grounding electrodes or union joint

M01

X1

T26-3.EPS

᭺: Available

–: Not available

Hydrostatic Test

The test verifies the absence of leaks by applying the following water

pressures (which are determined under process connection conditions) to

linings for ten minutes. Test results are described in the Note column of a

test certificate (QIC).

Water Pressure:

1.5 MPa

3.0 MPa

6.0 MPa

1.25 MPa

Process Connection:

ANSI Class 150, DIN PN10, JIS 10K

ANSI Class 300, DIN PN16, JIS 20K

DIN PN40, Union joint (Ceramics lining)

JIS F12

Calibration Certificate

Level 2: The Declaration and the Calibration Equipment List are issued.

Level 3: The Declaration and the Primary Standard List are issued.

Level 4: The Declaration and the Yokogawa Measuring Instruments Control

System are issued.

Enhanced Dual

Frequency Excitation

(*6)

Available for 25 to 200 mm (1.0 to 8.0 in.) sizes.

Products are delivered with the Standard dual frequency excitation mode

and the Enhanced dual frequency excitation mode enabled.

Although the meter factors for the Standard dual frequency excitation mode

and the Enhanced dual frequency excitation mode are inscribed on the

nameplate, the flow calibration of optional code HF1 is not performed in

Enhanced dual frequency excitation.Excitation mode select optional code

HF2 when an accurate flow measurement is required.

Available for 25 to 200 mm (1.0 to 8.0 in.) sizes.

Products are delivered with the Standard dual frequency excitation mode

and the Enhanced dual frequency excitation mode enabled.

The meter factor for the Enhanced dual frequency excitation obtained by

flow calibration is inscribed on the nameplate and set into the combined

converter in addition to the meter factor for the Standard dual frequency

excitation.

Vent Hole

With a vent hole provided for permeable fluids (such as nitric acid,

hydrofluoric acid, or sodium hydroxide at high temperature).

Available only for a PFA lining flange type tube.

H

HF1

HF2

T01

L2

L3

L4

Explosion proof

Remote

Flowtube

Integral

Flowmeter

Remote

Flowtube

Remote

Flowtube

Integral

Flowwmeter

Remote

Flowtube

Integral

Flowmeter

Oil-prohibited Use with

Dehydrating Treatment

Electrodes, linings, and grounding rings are assembled and packed with

polyethylene including desiccants after being cleaned with water and

acetone and dried with air. The label ‘OIL & WATER FREE’ is affixed.

Painting Color Change

Coated in black (Munsell N1.5 or its equivalent.)

Coated in jade green (Munsell 7.5 BG 4/1.5 or its equivalent.)

Coated in metallic silver.

K5

P1

P7

P2

AXF***G-

D

E

F

G

AXF***G-

N

P

AXF***C-

D

E

F

G

AXF***C-

N

P

AXF***W

-

N

P

AXF***H-

D

E

F

G

AXF***H-

N

P

Advertising