8. EXPLOSION PROTECTED TYPE INSTRUMENT

Temperature Code:

T0808.EPS

Temperature

Code

Maximum Process

Temperature

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

T6

Minimum Process

Temperature

T4

T5

T3

+70

°C (+158°F)

+85

°C (+185°F)

+120

°C (+248°F)

+150

°C (+302°F)

Ambient Temp.: –40

°C to +60°C (–40°F to +140°F)

(2) Installation

For CSA C22.2 Series

WARNING

• All wiring shall comply with Canadian Electrical

Code Part I and Local Electrical Codes.

• In hazardous location, wiring shall be in conduit

as shown in Figure 8.3.1.

WARNING : SEAL ALL CONDUITS WITHIN

50cm OF THE ENCLOSURE’.
UN SCELLEMENT DOIT ÉTRE
INSTALLÉ À MOINS DE 50cm DU
BOÎTIER.

• When installed in Division 2, “SEALS NOT

REQUIRED”

For CSA E79 Series

WARNING

• All wiring shall comply with local installation

requirements and local electrical code.

• In hazadous locations, the cable entry devices

shall be of a certified flameproof type, suitable
for the conditions of use and correctly installed.

• Unused apertures shall be closed with suitable

flameproof certified blanking elements. (The
plug attached is flameproof certified.)

(3) Operation

For CSA C22.2 Series

WARNING

WARNING : OPEN CIRCUIT BEFORE REMOV-

ING COVER.
OUVRIR LE CIRCUIT AVANT
D’ENLEVER LE COUVERCLE.

• Take care not to generate mechanical spark

when access to the instrument and peripheral
devices in hazardous locations.

For CSA E79 Series

(Integral Flowmeter)

WARNING

WARNING : AFTER DE-ENERGIZING, DELAY

20 MINUTES BEFORE OPENING.
APRÉS POWER-OFF, ATTENDRE
20 MINUTES AVANT D’OUVRIR.

• Take care not to generate mechanical spark

when access to the instrument and peripheral
devices in hazardous locations.

(Remote Flowtube)

WARNING

WARNING : DE-ENERGIZE BEFORE OPEN-

ING.
OUVRIR LE CIRCUIT AVANT
D’ENLEVER LE COUVERCLE.

• Take care not to generate mechanical spark

when access to the instrument and peripheral
devices in hazardous locations.

(4) Maintenance and Repair

WARNING

The instrument modification or parts replacement
by other than authorized representative of
YOKOGAWA Electric Corporation or
YOKOGAWA Corporation of AMERICA is
prohibited and will void Canadian Standards
Explosionproof Certification.

Conduit

Magnetic Flowmeter

Sealing Fitting

HAZARDOUS LOCATIONS

50 cm Max.

F0803.EPS

Figure 8.3.1 Conduit Wiring