Yokogawa ADMAG AXF User Manual

Page 94

Advertising
background image

IM 01E20D01-01E

6-32

6. OUTLINE

Table of Optional Specifications (Size 2.5 mm (0.1 in.) to 400 mm (16 in.)) (continued)

Standard

ϩ90-degree rotation ϩ180-degree rotation Ϫ90-degree rotation

Optional Code RC

Optional Code RA

Optional Code RB

Integral Flowmeter

Remote Flowtube

Electrical

Connection

Indicator

Electrical

Connection

Indicator

Electrical

Connection

Electrical

Connection

*1:

*3: Allowable temperature and pressure with the optional code BCC or BSC (only for Gaskets:Chloroprene rubber) are equivalent to Valqua #2010.

*4: Allowable temperature and pressure with the optional code BCF or BSF (only for Gaskets:PTFE-sheathed non-asbestos) are equivalent to Valqua #7030 (S).

*5: Special gaskets are inserted between the flowtube and the grounding ring or grounding electrode.

*6: Enhanced dual frequency excitation is not available for models with calibration code C (High Grade Accuracy).

*7: Applicable only for Australia, New Zealand, Singapore and India.

*8: Select optional code G12 or G11 when TIIS Flameproof type with wiring using a flameproof packing adapter. Available only for JIS G1/2 female electric connection.

*9: The TIIS flameproof type is only available for AXF***C-P (remote flowtube for combined use with AXFA14).

*10: In the case of Fieldbus communication type, optional codes C1, C2, C3, EM and G11 are unable to select.

T26-4.EPS

*2: When specifying the optional code BCC or BSC for a PFA

or ceramics lining, it is advisable to specify the optional

code GA, GC, or GD at the same time to prevent potential

leakage caused by the difference in elasticity between the

flowtube and chloroprene gaskets. Refer to description of

“Gasket” in the “Wetted Part Material”.

Code

Remote

Flowtube

Integral

Flowmeter

Remote

Flowtube

Remote

Flowtube

Integral

Flowmeter

Remote

Flowtube

Integral

Flowmeter

Submersible

Sanitary

Applicable Model

General

Item

Specifications

Five-point Calibration

in User-specified

Span

A flow test near 0, 25, 50, 75, and 100% of the user-specified span is

performed instead of the flow test of the standard 2m/s span and a test

certificate (QIC) is submitted. Specify the span (100% flow span) whose

corresponding flow velocity lies between 0.5 to 10 m/s (0.8 to 10m/s for

sizes 32, 65, and 125mm) and that is less than the maximum line capacity.

Selectable range of flow rate span is showing below.

Selectable range of flow rate span : m

3

/h

(Flow rate span velocity : m/s)

0.009 (0.5) to 0.05 (2.83)

0.036 (0.5) to

0.2 (2.83)

0.15 (0.5) to 0.96 (3.40)

0.32 (0.5) to

2.8 (4.40)

0.89 (0.5) to

11 (6.22)

2.32 (0.8) to 28.9 (10.00)

2.27 (0.5) to

28 (6.30)

3.54 (0.5) to

56 (7.92)

9.56 (0.8) to

80 (6.70)

9.05 (0.5) to

126 (6.96)

14.2 (0.5) to

190 (6.72)

35.3 (0.8) to

300 (6.79)

31.9 (0.5) to

380 (5.97)

56.6 (0.5) to

670 (5.92)

88.4 (0.5) to 1000 (5.66)

128 (0.5) to 1200 (4.72)

174 (0.5) to 1200 (3.47)

227 (0.5) to 1350 (2.98)

Size : mm

(in.)

2.5 (0.1)

5 (0.2)

10 (0.4)

15 (0.5)

25 (1)

32 (1.25)

40 (1.5)

50 (2)

65 (2.5)

80 (3)

100 (4)

125 (5)

150 (6)

200 (8)

250 (10)

300 (12)

350 (14)

400 (16)

SC

Explosion proof

FM Approval

FM Explosion proof

See “HAZARDOUS AREA CLASSIFICATION”

FF1

IECEx
Certification (*7)

IECEx Explosion proof

See “HAZARDOUS AREA CLASSIFICATION”

SF2

TIIS Certification

TIIS Flameproof

See “HAZARDOUS AREA CLASSIFICATION”

᭝ (*9)

JF3

Flameproof packing
adapter for TIIS
Flameproof Type (*8)

Two flameproof packing adapters

G12

One flameproof packing adapter and one blind plug.

Available for integral flowmeter and only when a four-wire cable is used for

power input and signal output with a DC power supply.

᭺ (*10)

G11

AXF***G-

D

E

F

G

AXF***G-

N

P

AXF***C-

D

E

F

G

AXF***C-

N

P

AXF***W

-

N

P

AXF***H-

D

E

F

G

AXF***H-

N

P

CSA Certification

CSA Explosion proof, Dual Seal

See “HAZARDOUS AREA CLASSIFICATION”

CF1

᭺: Available

–: Not available

ATEX Certification

ATEX Explosion proof

See “HAZARDOUS AREA CLASSIFICATION”

KF2