IM 01E20D01-01E

6-47

6. OUTLINE

Replacement model for Earlier ADMAG or ADMAG AE, AXF002-AXF015, Wafer Type, PFA Lining

D

Hi

49(1.93)

73

(2.87)

Hr

H1

ø86(3.38)

48

L*

2

Ground Terminal

(M4)

Ground Terminal

(M4)

ø128(5.04)

197(7.76)*

1

154(6.06)

111(4.37)

28(1.1)

66*

1

(2.6)

63.5

(2.50)

51.5

(2.03)

51.5

(2.03)

(1.89)

70(2.76)

ᮀ72
ᮀ58

3(0.12)

(шd

)

(2.83)

(2.28)

4- ш6.2(0.24)

002

2.5(0.1)

A

005

5(0.2)

A

010

10(0.4)

A

015

15(0.5)

A

85(3.35)

44(1.73)

15(0.59)

144(5.67)

265(10.43)

2.4(5.3)

306(12.03)

4.1(9.0)

*

3

Max. Height

Hr

Hi

Weight kg (lb)

Max. Height

Weight kg (lb)

Height

H1

Size code

Size

Lining code

Face-to-face

length

L

*

2

Outside dia.

D

Inner diameter of

Grounding ring

ø

d

Model

Remote
Flowtube

Integral
Flowmeter

Remote
Flowtube

Integral
Flowmeter

* No infra-red switches are furnished
for Fieldbus communication type.

Integral Flowmeter

Remote Flowtube

Integral Flowmeter

Remote Flowtube

Unit : mm (approx. inch)

*1: When indicator code N is selected, subtract 12 mm (0.47 inch)

from the value in the figure.

In case of explosion proof type with indicator, add 5 mm (0.2
inch) to it.

*2: Depending on the selection of grounding ring code and optional

code, add the following value to L (face-to-face length).

*3: When submersible type or option code DHC is selected,

waterproof glands and a 30m long cable are attached.

Add 9.5kg(20.9lb) to the weight in the table.

Option

Code

None

GA, GC, GD

(Special Gaskets)

Grounding Ring Code S, L, H, V

P, T

N

+0 +22(0.87) -6(0.24)

+2(0.08) +24(0.94)

F37.EPS

AXF002
AXF005
AXF010
AXF015

G

W

C

D
E

F

G
N

P

1
2

N

A

1

A

2

*4: D, E, F, G; Integral Flowmeter,

N, P; Remote Flowtube

*4

Replacement model for Earlier ADMAG or ADMAG AE, AXF025-AXF100, Wafer Type,

PFA /Polyurethane Rubber Lining

Integral Flowmeter Remote Flowtube

Integral Flowmeter

Remote Flowtube

Unit : mm (approx. inch)

F38.EPS

197(7.76)*

1

Hr

48(1.89)

ø86(3.38)

H1

154(6.06)

49(1.93)

Hi

L*

2

øD

(ød)

Ground Terminal

(M4)

111(4.37)

28(1.1)

66*

1

(2.6)

51.5

(2.03)

51.5

(2.03)

ø128(5.04)

70

(2.76)

73(2.87)

Ground Terminal

(M4)

*1: When indicator code N is selected, subtract 12 mm (0.47 inch)

from the value in the figure.

In case of explosion proof type with indicator, add 5 mm (0.2
inch) to it.

*2: Depending on the selection of grounding ring code and optional

*3: When submersible type or option code DHC is selected,

waterproof glands and a 30m long cable are attached.

Add 9.5kg(20.9lb) to the weight in the table.

Option

Code

None

GA, GC, GD

(Special Gaskets)

Grounding Ring Code S, L, H, V

P, T

N

+0 +22(0.87) -6(0.24)

+2(0.08) +24(0.94)

AXF025
AXF040
AXF050
AXF080
AXF100

G

W

C

D
E

F

G
N

P

1
2

N

A
U

1

A

2

*4: D, E, F, G; Integral Flowmeter,

N, P; Remote Flowtube

*4

025

25(1)

A,U

93(3.66)

67.5(2.66)

27(1.06)

92(3.62)

216(8.50)

3.1(6.7)

254(9.98)

4.8(10.5)

040

40(1.5)

A,U

106(4.17)

86(3.39)

40(1.57)

111(4.37)

235(9.25)

3.5(7.7)

273(10.73)

5.2(11.4)

050

50(2)

A,U

120(4.72)

99(3.90)

52(2.05)

129(5.08)

253(9.96)

4.2(9.3)

291(11.44)

5.9(13.1)

080

80(3)

A,U

160(6.30)

129(5.08)

81(3.19)

157(6.18)

281(11.06)

6.4(14.1)

319(12.54)

8.1(17.9)

100

100(4)

A,U

180(7.09)

155(6.10)

98(3.86)

183(7.20)

307(12.09)

8.0(17.6)

345(13.56)

9.7(21.3)

Model

Remote
Flowtube

Integral
Flowmeter

Remote
Flowtube

Integral
Flowmeter

*

3

Max. Height

Hr

Hi

Weight kg (lb)

Max. Height

Weight kg (lb)

Height

H1

Size code

Size

Lining code

Face-to-face

length

L

*

2

Outside dia.

ø

D

Inner diameter of

Grounding ring

ø

d

* No infra-red switches are furnished
for Fieldbus communication type.