6-45

6. OUTLINE

AXF Standard, AXF015-AXF125, Sanitary for Union Connection, PFA Lining

Integral Flowmeter

Remote Flowtube

Integral Flowmeter Remote Flowtube

Unit : mm (approx. inch)

F35.EPS

111(4.37)

48

(1.89)

70

(2.76)

73

(2.87)

154(6.06)

49

(1.93)

ш86(3.38)

28(1.1)

51.5

51.5

(2.03) (2.03)

197(7.76)*

1

66*

1

ш1

28(5.04)

Hr

H1

Hi

L

Ground Terminal

(M4)

Ground Terminal (M4)

(ød)

øD

Adapter for union
connection

H

F

G

ø

A

ø

B

ø

d

ø

E

ø

C

ø

A

ø

B

ø

d

ø

E

ø

F

H

G

ø

C

3

F

H

G

ø

A

ø

B

ø

C

ø

d

ø

E

Process

Connection

JKB (ISO2853 Union)

Nominal

Size

15

70

(2.76)

16

(0.63)

20

(0.79)

16

(0.63)

18

(0.71)

25.8

(1.02)
RD34

×1/8″

50

(1.97)

F9811

KR

25

70

(2.76)

22.2

(0.87)

30

(1.18)

26

(1.02)

30

(1.18)

39.8

(1.57)
RD52

×1/6″

50

(1.97)

F9811

KS

32

70

(2.76)

29.4

(1.16)

36

(1.42)

32

(1.26)

36

(1.42)

45.8

(1.80)
RD58

×1/6″

50

(1.97)

F9811

KT

40

83

(3.27)

34.6

(1.36)

42

(1.65)

38

(1.50)

42

(1.65)

51.8

(2.04)
RD65

×1/6″

50

(1.97)

F9811

KU

50

96

(3.78)

47.6

(1.87)

54

(2.13)

50

(1.97)

54

(2.13)

63.8

(2.51)
RD78

×1/6″

50

(1.97)

F9811

KV

65

114

(4.49)

59.5

(2.34)

70

(2.76)

66

(2.60)

71

(2.80)

80.8

(3.18)
RD95

×1/6″

50

(1.97)

F9811

KW

80

126

(4.96)

72.3

(2.85)

85

(3.35)

81

(3.19)

85

(3.35)

94.8

(3.73)

RD110

×1/4″

60

(2.36)

F9811

KX

100

152

(5.98)

97

(3.82)

104

(4.09)

100

(3.94)

104

(4.09)

113.8

(4.48)

RD130

×1/4″

60

(2.36)

F9811

KY

125

180

(7.09)

123

(4.84)

129

(5.08)

125

(4.92)

130

(5.12)

141.8

(5.58)

RD160

×1/4″

65

(2.56)

F9811

KZ

øA

øB

øC

ød

øE

øF

G

H

Parts No.

15

70

(2.76)

16

(0.63)

18

(0.71)

15.2

(0.60)

21.2

(0.83)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LA

25

70

(2.76)

22.2

(0.87)

25.6

(1.01)

22.6

(0.89)

29.2

(1.15)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LB

32

70

(2.76)

29.4

(1.16)

34.3

(1.35)

31.3

(1.23)

38.2

(1.50)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LC

40

83

(3.27)

34.6

(1.36)

38.6

(1.52)

35.6

(1.40)

42.7

(1.68)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LD

50

96

(3.78)

47.6

(1.87)

51.6

(2.03)

48.6

(1.91)

56.2

(2.21)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LE

65

114

(4.49)

59.5

(2.34)

64.1

(2.52)

60.3

(2.37)

69.9

(2.75)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LF

80

126

(4.96)

72.3

(2.85)

76.7

(3.02)

72.9

(2.87)

82.6

(3.25)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LG

100

152

(5.98)

97

(3.82)

102.5

(4.04)

97.6

(3.84)

108.7

(4.28)

13.5

(0.53)

3

(0.12)

50

(1.97)

F9811

LH

JDB (DIN 11851 Union)

JSB (SMS1145 Union)

25

70

(2.76)

22.2

(0.87)

25.4

(1.00)

22.5

(0.89)

32

(1.26)

11

(0.43)
RD40

×1/6″

50

(1.97)

F9811

LK

32

70

(2.76)

29.4

(1.16)

32

(1.26)

29.6

(1.17)

40

(1.57)

13

(0.51)
RD48

×1/6″

50

(1.97)

F9811

LL

40

83

(3.27)

34.6

(1.36)

38.1

(1.50)

35.5

(1.40)

48

(1.89)

15

(0.59)
RD60

×1/6″

50

(1.97)

F9811

LM

50

96

(3.78)

47.6

(1.87)

51

(2.01)

48.5

(1.91)

61

(2.40)

15

(0.59)
RD70

×1/6″

50

(1.97)

F9811

LN

65

114

(4.49)

59.5

(2.34)

63.5

(2.50)

60.5

(2.38)

73.5

(2.89)

19

(0.75)
RD85

×1/6″

50

(1.97)

F9811

LP

80

126

(4.96)

72.3

(2.85)

76.2

(3.00)

72.9

(2.87)

86

(3.39)

19

(0.75)
RD98

×1/6″

50

(1.97)

F9811

LQ

100

152

(5.98)

97

(3.82)

102.5

(4.04)

97.6

(3.84)

120

(4.72)

30

(1.18)

RD132

×1/6″

65

(2.56)

F9811

LR

*1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the

figure.

*2: When option code DHC is selected, waterproof glands and a 30m long cable are

attached. Add 9.5kg (20.9lb) to the weight in the table.

AXF015
AXF025
AXF032
AXF040
AXF050
AXF065
AXF080
AXF100
AXF125

H

D
E

F

G
N

P

1
2

N

A L 1 N

J
J
J

K
D
S

B
B
B

1

JKB:

JDB:

JSB:

Adapters for union connection

(2.6)

*3: D, E, F, G; Integral Flowmeter,

N, P; Remote Flowtube

*3

Max. Height

Hr

Hi

Max. Height

Weight kg (lb)

Height

H1

Size code

Process Connection

JKB / JDB / JSB

Size

Lining code

Face-to-face

length

L

Outside dia.

Inside dia.

ø

D

ø

d

JDB

JSB

JKB

JDB

JSB

JKB

Model

Remote
Flowtube

Integral
Flowmeter

Remote
Flowtube

Integral
Flowmeter

015

15

(0.5)

A

166

(6.55)

166

(6.55)

73

(2.87)

15.2

(0.60)

16

(0.63)

98

(3.86)

222

(8.74)

2.6

(5.7)

260

(10.24)

4.3

(9.5)

025

25

(1)

A

166

(6.55)

166

(6.55)

166

(6.55)

73

(2.87)

22.6

(0.89)

26

(1.02)

22.5

(0.89)

98

(3.86)

222

(8.74)

2.6

(5.7)

260

(10.24)

4.3

(9.5)

032

32

(1.3)

A

166

(6.55)

166

(6.55)

166

(6.55)

73

(2.87)

31.3

(1.23)

32

(1.26)

29.6

(1.17)

98

(3.86)

222

(8.74)

2.7

(6.0)

260

(10.24)

4.4

(9.7)

040

40

(1.5)

A

166

(6.55)

166

(6.55)

166

(6.55)

86

(3.39)

35.6

(1.40)

38

(1.50)

35.5

(1.40)

111

(4.37)

235

(9.25)

3

(6.6)

273

(10.73)

4.7

(10.4)

050

50

(2)

A

176

(6.94)

176

(6.94)

176

(6.94)

99

(3.90)

48.6

(1.91)

50

(1.97)

48.5

(1.91)

129

(5.08)

253

(9.96)

3.8

(8.4)

291

(11.44)

5.5

(12.1)

065

65

(2.6)

A

196

(7.73)

196

(7.73)

196

(7.73)

117

(4.61)

60.3

(2.37)

66

(2.60)

60.5

(2.38)

147

(5.79)

271

(10.67)

4.9

(10.8)

309

(12.17)

6.6

(14.6)

080

80

(3)

A

216

(8.52)

236

(9.31)

216

(8.52)

129

(5.08)

72.9

(2.87)

81

(3.19)

72.9

(2.87)

157

(6.18)

281

(11.06)

5.9

(13.0)

319

(12.54)

7.6

(16.8)

100

100

(4)

A

246

(9.70)

266

(10.49)

276

(10.88)

155

(6.10)

97.6

(3.84)

100

(3.94)

97.6

(3.84)

183

(7.20)

307

(12.09)

8.2

(18.1)

345

(13.56)

9.9

(21.8)

125

125

(5)

A

326

(12.85)

183

(7.20)

125

(4.92)

212

(8.35)

336

(13.23)

13

(28.7)

374

(14.70)

14.7

(32.4)

*

2

Weight kg (lb)

* No infra-red switches are furnished
for Fieldbus communication type.

Advertising