6. OUTLINE

Table of Optional Specifications (Size 500 mm (20 in.) to 2600 mm (104 in.))

AXF***W

-N

Submersible

AXF***G-N

General

Applicable Model

Item

Specifications

For District Heating

and Cooling or

Condensation-proof

Urethane resin potting is applied in the terminal box of a remote flowtube. Select JIS G1/2 for the electrical

connections. 30-meter dedicated and excitation cables are pre-wired and waterproof glands with union joints are

attached at factory.

DHC

User-specified Signal

and Excitation Cable

Length

Available for the submersible type and a model with optional code DHC. The cable length is limited up to 200 meters

when combined with an AXFA11 converter. Following “L,” specify the cable length in three digits as a multiple of 1

meter (e. g., 001, 002, or 005) for a length up to 5 meters, or as a multiple of 5 meters (i.e., 005, 010, 015, or the like)

for a length of 5 meters or more. If this optional code is not selected, a 30-meter length cable is attached.

L***

Mass Unit Setting

The flow rate span, transmission pulse weight, and totalizer display pulse weight can be set in terms of mass unit.

Specify the density of the process fluid when ordering in addition to the mass flow rate span, transmission pulse

weight (for mass unit), and totalizer display pulse weight (for mass unit).

When ordering a remote flowtube, parameters for 'Mass Unit Setting' will be set in the corresponding converter before

shipment.

1. Density

a. Available density Numerics:

Specify the numeric within the value of 500 to 2000 kg/m

3

, 4.2 to 16.7 lb/gal, or 31.2 to 124.8 lb/cf. And it can be

up to five digits, to a maximum of 32000 ignoring the decimal point. A fraction is limited to the fourth decimal place.

b. Available density units: kg/m

3

, lb/gal, lb/cf

Example: A water density is about 1000kg/m

3

. In this case specify “1000kg/m

3

”.

However a density is changed by temperature. Specify the actual density.

(The 1000kg/m

3

is equivalent to 8.345lb/gal and 62.43lb/cf.)

2. The mass flow rate span, transmission pulse weight, and totalizer display pulse weight

a. Available density Numerics:

Specify the numeric within the value of 0.0001 to 32000. And it can be up to five digits, to a maximum of

32000 ignoring the decimal point. A fraction is limited to the fourth decimal place.

b. Mass Units Available mass units: t, kg, g, klb, lb

Available time units: /d, /h, /min, /s

Note1: In case of specifying the mass flow span, calculate the volumetric flow span by the setting density, and specify

the available value in the mass flow span.

Note2: In case of transmission pulse weight and totalizer display pulse weight, specify the mass unit which was

specified as the flow unit.

MU

G3/4 Female

Waterproof Glands

Waterproof glands for G3/4 conduits or flexible tubes are attached to the electrical connections. Available only for JIS

G1/2 female electric connections.

EW

Direction Change of

Electrical Connection (*1)

+90 degrees rotated terminal box to change the direction of the electrical connection. Available for 1000 mm

(40 in.) and smaller sizes.

RA

Material certificates are provided for pipe, electrodes, grounding rings, and flanges.

M01

+180 degrees rotated terminal box to change the direction of the electrical connection. Available for 1000 mm (40 in.)

and smaller sizes.

RB

–90 degrees rotated terminal box to change the direction of the electrical connection. Available for 1000 mm (40 in.)

and smaller sizes.

RC

Waterproof Glands

Waterproof glands are attached to the electrical connections. Available only for JIS G1/2 female electric connections.

EG

Waterproof Glands

with Union Joints

Waterproof glands with union joints are attached to the electrical connections. Available only for JIS G1/2 female

electric connections.

EU

Stainless Steel Tag

Plate

Screwd JIS SUS304 (AISI 304 SS/EN 1.4301 stainless steel equivalent) stainless steel tag plate for size 1100 to 2600

mm, or a pendant tag plate of JIS SUS304 is provided for size 500 to 1000 mm. Choose this option when a SS tag

plate is required in addition to the standard nameplate with the tag number inscribed on it.

Dimension (Height

ϫ Width): Appr. 12.5 (4.92) ϫ 40 (15.7) mm (inch)

SCT

Material Certificate

Standard

ϩ90-degree rotation ϩ180-degree rotation Ϫ90-degree rotation

Optional Code RC

Optional Code RA

Optional Code RB

Remote Flowtube

Electrical

Connection

Electrical

Connection

*1:

T26-5.EPS

Code

Remote

Flowtube

Remote

Flowtube

᭺: Available

–: Not available