Yokogawa ADMAG AXF User Manual

Page 89

Advertising
background image

IM 01E20D01-01E

6-27

6. OUTLINE

REPLACEMENT MODEL FOR EARLIER ADMAG OR ADMAG AE (Flange Type)

General-purpose Use/Submersible Type/Explosion proof Type, PFA/Polyurethane Rubber Lining
For Flange Types of size 15 mm (0.5 in.) to 100 mm (4.0 in.), 300 mm (12 in.) to 2600 mm (104 in.), AXF Standard shall be
selected.

Use

Converter

Output Signal

and

Communication

Power Supply

Lining (*7)

Electrode Material (*7)

General-Purpose Use

Submersible Type

Explosion proof Type (*4)

Integral Flowmeter with 4 to 20 mA DC Output and BRAIN Communication

Integral Flowmeter with 4 to 20 mA DC Output and HART Communication

Integral Flowmeter with Digital communication

(F

OUNDATION

Fieldbus protocol) (*8)

Integral Flowmeter with Digital communication

(PROFIBUS PA protocol) (*9)

Remote Flowtube for Combined Use with AXFA11

Remote Flowtube for Combined Use with AXFA14

Integral Flowmeter, 100 V to 240 V AC or 100 to 120 V DC

Integral Flowmeter, 24 V AC/DC

Remote Flowtube

JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)

Platinum-iridium

Hastelloy C276 Equivalent

Tantalum

Titanium

Tungsten Carbide

Non-replaceable

Replaceable

None

JIS SUS316 (AISI 316 SS/EN 1.4401 Equivalent)

JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)

Platinum-iridium

Hastelloy C276 Equivalent

Tantalum

Titanium

-D · · · · · · · · · · · · · · · · · ·

-E · · · · · · · · · · · · · · · · · ·

-F · · · · · · · · · · · · · · · · · ·

-G · · · · · · · · · · · · · · · · · ·

-N · · · · · · · · · · · · · · · · · ·

-P · · · · · · · · · · · · · · · · · ·

Fluorocarbon PFA

Polyurethane Rubber

Grounding Ring and

Grounding Electrode

Material (*7)

Size150 mm (6.0 in.), 200 mm (8.0 in.),

PFA lining only

Size150 mm (6.0 in.), 200 mm (8.0 in.),

PFA lining only

Process Connection

(*2)(*10)

ANSI Class 150

Flange (Carbon Steel)

ANSI Class 300

Flange (Carbon Steel)

DIN PN 10

Flange (Carbon Steel)(*1)

DIN PN 16

Flange (Carbon Steel)(*1)

JIS 10K

Flange (Carbon Steel)

JIS 20K

Flange (Carbon Steel)

JIS F12 (JIS75M)

Flange (Carbon Steel)

Size 150 mm (6.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Size 150 mm (6.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Size 200 mm (8.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Size 150 mm (6.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Size 150 mm (6.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Size 150 mm (6.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Size 150 mm (6.0 in.) to 250 mm (10 in.),

Not available for TIIS flameproof type

Lay Length

2 · · · · · · · Matches an Earlier ADMAG Flowmeter (ADMAG or ADMAG AE) for Replacement

Electrical Connection (*5)

Optional code (See the Table of Optional Specifications)

Standard

B · · ·

Calibration

Integral Flowmeter with indicator (Horizontal)

Integral Flowmeter with indicator(Vertical)

Integral Flowmeter without indicator /Remote Flowtube

Indicator (*3)(*6)

-0 · · · ·

-2 · · · ·

-4 · · · ·

JIS G1/2 female

ANSI 1/2 NPT female

ISO M20

ϫ1.5 female

1 · · ·

2 · · ·

N · · ·

/

ٗ

Electrode Structure

-CA1 · · · · · · ·

-CA2 · · · · · · ·

-CD1 · · · · · · ·

-CD2 · · · · · · ·

-CJ1 · · · · · · ·

-CJ2 · · · · · · ·

-CG1 · · · · · · ·

N · · · · · · · · · · ·

S · · · · · · · · · · ·

L · · · · · · · · · · ·

P · · · · · · · · · · ·

H · · · · · · · · · · ·

T · · · · · · · · · · ·

V · · · · · · · · · · ·

1 · · · · · · · · · · · · ·

2 · · · · · · · · · · · · ·

L · · · · · · · · · · · · ·

P · · · · · · · · · · · · ·

H · · · · · · · · · · · · ·

T · · · · · · · · · · · · ·

V · · · · · · · · · · · · ·

W · · · · · · · · · · · · ·

1 · · · · · · · · · · · · · · · ·

2 · · · · · · · · · · · · · · · ·

N · · · · · · · · · · · · · · · ·

A · · · · · · · · · · · · · ·

U · · · · · · · · · · · · · ·

G · · · · · · · · · · · · · · · · · · · · ·

W · · · · · · · · · · · · · · · · · · · · ·

C · · · · · · · · · · · · · · · · · · · · ·

Model

Suffix Code

Description

Applicable Model

AXF150

AXF200

AXF250

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

Size 150 mm (6.0 in.) Integral Flowmeter/Remote Flowtube

Size 200 mm (8.0 in.) Integral Flowmeter/Remote Flowtube

Size 250 mm (10 in.) Integral Flowmeter/Remote Flowtube

T20.EPS

Remote Flowtube only

PFA lining only

PFA lining only

PFA lining only

General-Purpose use,Electrode Material :

JIS SUS316L only

Not available for Submersible Type

Not available for Submersible Type

Advertising