4-34

IM MV1000-17E

YQ

Sets the application timeout

To not use the timeout feature

Syntax

YQ p1<terminator>
p1 Application timeout (OFF)

Query

YQ?

Example Disable timeout.

YQOFF

Description The settings specified with this command take

effect when you save the settings with the XE
command and power-cycle the MV.

To use the timeout feature

Syntax

YQ p1,p2<terminator>
p1 Application timeout (ON)
p2 Timeout value [minutes] (1 to 120)

Query

YQ?

Example Enable the application timeout and set the

timeout value to 3 min.
YQON,3

Description The settings specified with this command take

effect when you save the settings with the XE
command and power-cycle the MV.

YT

Sets the FTP transfer timing

Syntax

YT p1,p2,p3<terminator>
p1 Auto transfer when display and event data

files are generated (ON/OFF)

p2 Auto transfer when report data files are

generated (ON/OFF)

p3 Auto transfer when snapshot data files are

generated (when snapshot is executed) (ON/
OFF)

Query

YT?

Example Auto transfer display and event data files. Do not

transfer report data files. Do not transfer image
data files.
YTON,OFF,OFF

Description If the method to save data to an external storage

medium is set to Auto, the MV automatically
transfers data files as they are generated.
For media storage settings, see the MV1000/
MV2000 User’s Manual
.

YU

Sets the contents to be sent via

e-mail

To send changes in the alarm status

Syntax

YU p1,p2,p3,p4,p5,p6,p7,p8,p9,p10,

p11,p12<terminator>

p1 Transmitted content (ALARM)
p2 Recipient 1 ON/OFF
p3 Recipient 2 ON/OFF
p4 Alarm transmission of alarm number 1 ON/OFF
p5 Alarm transmission of alarm number 2 ON/OFF
p6 Alarm transmission of alarm number 3 ON/OFF
p7 Alarm transmission of alarm number 4 ON/OFF
p8 Include instantaneous data ON/OFF

p9 Include source URL ON/OFF
p10 Subject (up to 32 alphanumeric characters)
p11 Header 1 (up to 64 characters)
p12 Header 2 (up to 64 characters)

Query

YU[ p1]?

Example Transmit alarms of alarm numbers 1 to 4

including instantaneous data but not including
the source URL to recipient 1. Set the subject to
“ALM” and header 1 to “LP2.”
YUALARM,ON,OFF,ON,ON,ON,ON,ON,OFF,AL
M,LP2

To send e-mail at scheduled times

Syntax

YU p1,p2,p3,p4,p5,p6,p7,p8,p9,p10,
p11,p12<terminator>
p1 Transmitted content (TIME)
p2 Recipient 1 ON/OFF
p3 Interval for sending e-mail to recipient 1

(1H, 2H, 3H, 4H, 6H, 8H, 12H, 24H)

p4 Time when e-mail is sent to recipient 1 (00:00

to 23:59)

p5 Recipient 2 ON/OFF
p6 Interval for sending e-mail to recipient 2

(1H, 2H, 3H, 4H, 6H, 8H, 12H, 24H)

p7 Time when e-mail is sent to recipient 2 (00:00

to 23:59)

p8 Include instantaneous data ON/OFF
p9 Include source URL ON/OFF
p10 Subject (up to 32 alphanumeric characters)
p11 Header 1 (up to 64 characters)
p12 Header 2 (up to 64 characters)

Query

YU[ p1]?

Example Send e-mail at 17 hours 15 minutes every day

to recipient 1. Do not include instantaneous data
but include the source URL. Set the subject to
“GOOD” and header 1 to “LP2.”
YUTIME,ON,24H,17:15,OFF,,,OFF,ON,
GOOD,LP2

To send system notifications

Syntax

YU p1,p2,p3,p4,p5,p6,p7<terminator>
p1 Transmitted content (SYSTEM)
p2 Recipient 1 ON/OFF
p3 Recipient 2 ON/OFF
p4 Include source URL ON/OFF
p5 Subject (up to 32 alphanumeric characters)
p6 Header 1 (up to 64 characters)
p7 Header 2 (up to 64 characters)

Query

YU[ p1]?

Example Send system notification e-mail messages

including the source URL to recipient 1. Set the
subject to “SystemAlert” and header 1 to “LP2.”
YUSYSTEM,ON,OFF,ON,SystemAlart,LP2

To send report generation notifications

Syntax

YU p1,p2,p3,p4,p5,p6,p7<terminator>
p1 Transmitted content (REPORT)
p2 Recipient 1 ON/OFF

4.6 Basic Setting Commands