Manually Sampled Data and Report Data Information

The MV returns manually sampled and report data information in response to an MO
command.

• Syntax

EACRLF
slll···_yy/mo/dd_hh:mm:ss_bbbb_fff···CRLF
··········································
ENCRLF

s Data flag
Space Confirmed data

+: Data that was overwritten
*: Data being added

lll··· File number (10 digits)
yy Year (00 to 99)
mo Month (01 to 12)
dd Day (01 to 31)
hh Hour (00 to 23)
mm Minute (00 to 59)
ss Second (00 to 59)
bbbb Number of events (four characters)
fff··· File name (up to 48 characters including the extension)
_ Space

• Example

EA
+ 6 05/03/04 00:00:00 20 aaaa30312345.DAR
7 05/03/05 00:00:00 20 30400005.DAR
8 05/03/06 00:00:00 20 30500005.DAR
* 9 05/03/06 13:00:00 20 uuuu0005.DAR