Yokogawa Button Operated MV2000 User Manual

Page 78

Advertising
background image

4-4

IM MV1000-17E

Note

• There are two execution modes on the MV. If you attempt to execute a command in the

wrong mode, a syntax error will occur. Use the DS command to switch to the appropriate
execution mode, and then execute the command. Query commands can be executed in
either mode.

Basic Setting Mode

A mode in which settings are changed after stopping measurements and computations.

Operation Mode

A mode in which commands other than those in Basic Setting Mode are used.
• The administrator and user indications in the table are the user levels that are specified

through the Ethernet communication login function. See section 2.1 for details.

Group/

Command Name

Function

Execution

Mode

Administrator User See

Page

Control
BT

Sets a batch name

Operation Mode Yes

No

4-24

BU

Sets a batch comment

Operation Mode Yes

No

4-24

UD

Switches the display

Operation Mode Yes

No

4-24

PS

Starts/stops measurements

Operation Mode Yes

No

4-25

AK

Releases the alarm output (alarm acknowledge)

Operation Mode Yes

No

4-25

EV

Executes manual sample, manual trigger, snapshot,

or forced timeout

Operation Mode Yes

No

4-25

CL

Executes manual SNTP

Operation Mode Yes

No

4-25

CV

Switches the trend interval

Operation Mode Yes

No

4-25

MS

Writes a message (displays and writes)

Operation Mode Yes

No

4-25

BJ

Writes a free message

Operation Mode Yes

No

4-25

EJ

Changes the login password

Operation Mode Yes

Yes

4-25

TL

Starts, stops, resets computation (MATH) or clears

the computation dropout status display

Operation Mode Yes

No

4-26

DS

Switches the execution mode between operation and

basic setting

All modes

Yes

No

4-26

LO

Loads setup data

Operation Mode Yes

No

4-26

LI

Saves setup data

Operation Mode Yes

No

4-26

CM

Sets communication input data

Operation Mode Yes

No

4-26

CE

Enters data in an external input channel

Operation Mode Yes

No

4-26

EM

Starts/stops the e-mail transmission

function

Operation Mode Yes

No

4-27

CU

Manually recovers Modbus

Operation Mode Yes

No

4-27

BV

Enters characters

*

All modes

Yes

No

4-27

KE

Key operation command

Operation Mode Yes

No

4-27

YC

Clears measured/computed data and initializes setup

data

Basic Setting

Mode

Yes

No

4-27

IR

Resets a relative timer

Operation Mode Yes

No

4-27

MA

Resets a match timer

Operation Mode Yes

No

4-27

NR

Sets the trend interval

Operation Mode Yes

No

4-27

Yes: Command usable

No: Command not usable

* Can only be used in serial communications.

4.2 A List of Commands

Advertising
This manual is related to the following products: