20 error recovery procedure – Triton 97XX Series Operation Manual User Manual

Page 243

Advertising
background image

TRITON SYSTEMS, INC.

SECTION 8 - ERROR RECOVERY

O

PERATION

M

ANUAL

- M

ODEL

97XX-Series

8-20

ERROR RECOVERY PROCEDURE

13

1.

Turn off the Cash Dispenser and open the security container.

2.

Inspect the EJ Module. The EJ should be yellow in color.

3.

Close and lock the security container.

4.

If the EJ Module is the correct color, reset the Cash Dispenser.

5.

If the error clears, perform a Test Dispense.

6.

If the dispense works, place the unit back in service.

7.

If the test dispense does not work, the error occurs again, or
the EJ Module is not yellow in color, contact your service pro-
vider.

This Procedure applies to
the following error codes:

193