Bad Battery/Battery Replacement

If the lock beeps repeatedly while open, or beeps twice and re-
fuses to open, the 9-volt battery, located in the battery box on
the inside of the door
, is weak or dead and needs to be replaced.

Note: If the lock will not operate (i.e. no signal from the panel when
a button is pressed) while the door is closed and locked, the bat-
tery is dead and the lock must be energized from the two external
terminals on the front, right side of the push-button panel.

To energize the lock, connect a 9-volt battery across the external
terminals with the negative terminal of the battery facing up. Con-
tinue to hold the battery against the terminals as you enter
the combination and open the lock.

Follow these steps to replace a battery:

1.

Open the ATM vault door. If the battery box is visible on the
back panel of the door, continue with Step 2, below. If the
battery box is not visible, the bolt-works panel must be
removed.
Remove the eight screws from the bolt-works panel
on the back side of the door. The battery box will be visible.

2.

Pull gently on the front cover of the battery box and slide the
cover off.

3.

Remove the old battery. Install a new battery and replace the
front cover.

4.

Verify the lock is working correctly.

5.

If the bolt-works panel was removed in Step 1, replace the
panel and secure it in place using the eight installation
screws
. Close and lock the ATM vault door.