Triton RL5000 User Manual User Manual

Page 83

Advertising
background image

6 3

M

ANAGEMENT

F

UNCTIONS

F

ACTORY

D

EFAULT

: A

LL

S

ELECTED

C

ASSETTE

(

S

) I

N

-S

ERVICE

A

CCESS

I

NSTRUCTIONS

:

1.

From the MAIN MENU screen,
select the TERMINAL CLOSE
FUNCTIONS option by press-
ing number (1) on the keypad.

2.

To access the CASSETTE
CLOSE FUNCTIONS menu,
press number (6) on the keypad.

3.

After replenishing cassette(s),
select which cassette(s) to put
IN-SERVICE.

D

ESCRIPTION

:

In a multi-cassette configuration, individual cassettes can be placed in service. This
means the selected cassettes will be used by the ATM for meeting withdrawal
requests.

Select the cassette(s) to place I

N

-S

ERVICE

. A checkmark identifies which cassette(s)

are selected. The number of available cassette selections will depend on the number
of installed cassettes. Press Enter after selection.

The dispenser will automatically lock the cassettes and a dialog prompt will be
displayed.

*NOTE*

In a multi-cassette configuration, the cassettes MUST be LOCKED
and IN-SERVICE for normal operation.