Rl5000 s – Triton RL5000 User Manual User Manual

Page 96

Advertising
background image

7 6

M

ODEL

RL5000 S

ERIES

U

SER

M

ANUAL

F

ACTORY

D

EFAULT

: N/A

A

CCESS

I

NSTRUCTIONS

:

1.

From the MAIN MENU screen,
select the DIAGNOSTICS option
by pressing number (2) on the key-
pad.

2.

Enter the DISPENSER diagnostics
menu by pressing number (4) on the
keypad.

3.

To force the dispenser to complete
a PURGE, press number (2) on the
keypad.

4.

Press the ENTER key when the
PURGE dialog screen appears

5.

To complete a TEST DISPENSE,
press number (3) on the keypad.
Select the number of notes to pick
during a Test Dispense and press
the ENTER key.

P

URGE

/ T

EST

D

ISPENSE

The T

EST

D

ISPENSE

command instructs the dispensing mechanism to dispense, mini-

mum, one note from each installed and operational cassette into the reject area.

This test exercises the dispenser mechanism without sending notes to the exit.

D

ESCRIPTION

:

The P

URGE

command instructs the dispenser to remove all documents from the feed

path. When the purge command is used to clear the feed path following a jam or
failure of the dispenser, some or all of the notes may pass out of the exit slot,
depending on their location in the feed path and the type of fault condition.

Advertising