HP XP7 Storage User Manual

Page 222

Advertising
background image

Table 46 Command error messages (continued)

Value

Recommended action

Condition

Error

message

Error code

230

Please confirm the command name.

An unknown command was
attempted.

Unknown command

EX_UNWCMD

229

Please confirm the pair status using
the pairdisplay command.

The pair status of a volume
within a group is not
identical to the status of the
other volumes in the group.

Inconsistent status in
group

EX_INCSTG

228

Please confirm the pair status using
the pairdisplay command.

The pair status of the target
volume is not appropriate.

Invalid pair status

EX_INVSTP

222

Please confirm the volume status
using the pairdisplay -l or the
raidvchkdsp -v aou command.

The volume status of the
target volume is not
appropriate.

Invalid volume status

EX_INVVOL

220

Please confirm the MU# (MU #1/2
cannot be used for Continuous

The MU# of the volume to
be operated is not
appropriate.

Invalid mu# with
HORC/UR or
HOMRCF

EX_INVMUN

Access Synchronous and must be
P-VOL for Business Copy.) for the
specified group using the
pairdisplay

command. And also

confirm the command execution
environment to be set as HOMRCF.

227

Please confirm that the Port, Target
ID, LUN are defined correctly under

A device defined in the
configuration file does not

No such LDEV within
the RAID

EX_ENLDEV

HORCM_DEV in the configuration
file.

have a mapping to a real
LUN and target ID within the
RAID storage system.

226

Contact the HP Technical Support.

Wrong return code.

Invalid return code

EX_INVRCD

225

Check the volume list to see if an
operation was directed to the wrong
S-VOL.

Currency check error for
S-VOL. Cannot guarantee
identical data on S-VOL.

S-VOL currency error

EX_VOLCUR

224

Please confirm the pair status of the
local volume using the pairdisplay
command.

The volume specified with
the SVOL-takeover command
is not the same as the P-VOL.

Local volume
currency error

EX_VOLCUE

223

Please confirm the pair status of
remote and local volumes using the
pairdisplay

command.

The combination of the
volumes specified with
Swap-takeover is unsuitable.

Local and remote
volume currency
error

EX_VOLCRE

--

Contact the HP Technical Support.

Wrong error code.

Unknown error
code.

EX_UNWERR

217

Please create a pair with cutting the
number of the group on the

When creating Continuous
Access Synchronous

Not enough CT
groups in RAID

EX_ENOCTG

configuration files or make already

Async/UR or Business Copy

existing group and the target group

volume, CTGID could not be

the same CTGID. Please confirm

registered due to being

already existing group CTGID using

beyond the max number of

the pairvolchk command. Then,

CT groups (0-255 for
P9500, XP24000/XP20000 please create a pair specifying
Disk Array, 0-255 for

CTGID as the paircreate -f
option.

XP12000 Disk
Array/XP10000 Disk Array,
0-127 for XP1024/XP128
Disk Array, 0-15 for XP256
Disk Array) for an async
volume.

222 Troubleshooting

Advertising
This manual is related to the following products: