HP XP7 Storage User Manual

Page 259

Advertising
background image

Table 79 SSB codes that are returned by raidcom delete pool command (continued)

raidcom delete pool

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

Pool ID is not installed.

6000

2E20

Executing/Async

CMDRJE

Get Command Status

The operation cannot be performed because the shared memory
(SM) is not initialized.

8106

2E21

Async

Get Command Status

The number of specified LDEVs is invalid.

0008

2E23

Executing

CMDRJE

The specified LDEV cannot be deleted because it is a top VOL
of the pool.

0052

2E30

Executing

CMDRJE

The specified pool is a pool for Fast Snap or Snapshot.

6003

2E30

Executing

CMDRJE

The command cannot be accepted. After a while, execute the
same command.

00EE

2EE7

Executing

CMDRJE

Pool ID is not installed.

00F9

2EE7

Executing

CMDRJE

An internal error occurred.

FEEC

2EE7

Executing

CMDRJE

Call HP Technical Support.

The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.

6002

2EF3

Executing

CMDRJE

Table 80 SSB codes that are returned by raidcom add snap_pool command

raidcom add snap_pool

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The value of LDEV number is out of range.

0000

2E00

Async

Get Command Status

Pool ID is out of range.

6000

2E00

Executing

CMDRJE

The type of pool is invalid.

6001

2E00

Executing

CMDRJE

The maximum reserve ratio for V-VOL is out of range.

6002

2E00

Executing

CMDRJE

The operation cannot be done because a SATA-E drive in the
state of quick formatting is in the specified LDEV.

000C

2E10

Async

Get Command Status

The specified LDEV is in the state of blocked.

0009

2E10

Async

Get Command Status

The specified LDEV is in the state of blocked, or not installed.

0011

2E10

Executing

CMDRJE

Fast Snap cannot be used because there are not enough cache
management devices to create pairs.

0050

2E10

Async

Get Command Status

The pool cannot be created because there are not enough
resources (VDEV) depending on cache management devices.

0102

2E10

Async

Get Command Status

The operation cannot be performed because the pool volume
is being deleted.

600D

2E10

Async

Get Command Status

The pool is not in the status where the pool volume can be
added.

6003

2E11

Executing

/Async

CMDRJE

Get Command Status

The operation cannot be done because the power supply is
switched off.

8003

2E11

Async

Get Command Status

Error messages and error codes 259

Advertising