HP XP7 Storage User Manual

Page 94

Advertising
background image

Example of the configuration definition files when specifying a virtual storage machine by
HORCM_VCMD

Example of the configuration definition files (HORCM0)

The underlined parts indicate the information that needs to modify from the file of the old model.

#/******** HORCM0 on PHOST *****/
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
NONE horcm0 1000 3000

#/********** For HORCM_CMD ****************/
HORCM_CMD
#dev_name
\\.\CMD-367000:/dev/rdsk
HORCM_VCMD
# redefine Virtual DKC Serial# as unitIDs
365000

HORCM_LDEV
Ora dev1 365000 02:00 h1
Ora dev2 365000 02:01 h1

#/********** For HORCM_INST ****************/
HORCM_INST
#dev_group ip_address service
Ora RHOST horcm1

Example of the configuration definition files (HORCM1)

The underlined parts indicate the information that needs to modify from the file of the old model.

#/******** HORCM1 on RHOST *****/
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
NONE horcm1 1000 3000

#/********** For HORCM_CMD ****************/
HORCM_CMD
#dev_name
\\.\CMD-368000:/dev/rdsk
HORCM_VCMD
# redefine Virtual DKC Serial# as unitIDs
366000

HORCM_LDEV
Ora dev1 366000 02:00 h1
Ora dev2 366000 02:01 h1

#/********** For HORCM_INST ****************/
HORCM_INST
#dev_group ip_address service
Ora PHOST horcm0

The raidqry command display example

# raidqry -l
No Group Hostname HORCM_ver Uid Serial# Micro_ver Cache(MB)
1 --- raidmanager 01-31-03/00 0 66000 80-01-00/00 81920

94

RAID Manager functions on the P9500 and XP7 Storage

Advertising