Table 82 SSB codes returned by raidcom modify snapshot (continued)

raidcom modify snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

The Fast Snap or Snapshot pair cannot be restored due to
one of the following reasons:

9704

2E10

Executing

CMDRJE

Snapshot data of a restore target Fast Snap or Snapshot
pair is being obtained per consistency group.

Snapshot data of a different pair whose primary volume
is the restore target P-VOL of a Fast Snap or Snapshot
pair is being obtained per consistency group.

An error occurred at the operation of Fast Snap due to one
of the following reasons:

9800

2E10

Executing

CMDRJE

The LDEV number specified for the P-VOL or the S-VOL
is incorrect.

The LDEV specified as the P-VOL or the S-VOL is not
paired.

The pair of the specified P-VOL or the S-VOL is not ready
to perform the specified operation.

The specified Snapshot ID (MU number) is wrong.

The specified Snapshot ID (MU number) is already used.

The specified pool is not in the usable status.

The license capacity has exceeded the maximum.

The control table for Fast Snap is depleted.

The operation cannot be performed because power-off is in
progress.

8003

2E11

Executing

CMDRJE

The specified LDEV is not defined.

0000

2E20

Executing

CMDRJE

The command ends abnormally because an unmounted
volume is specified as the P-VOL of a Fast Snap or Snapshot
pair.

0008

2E20

Executing

CMDRJE

The command ends abnormally because the blocked volume
is specified as the P-VOL of a Fast Snap or Snapshot pair.

0009

2E20

Executing

CMDRJE

The command ends abnormally because the volume in
formatting operation is specified as the P-VOL of a Fast Snap
or Snapshot pair.

000A

2E20

Executing

CMDRJE

The command ends abnormally because the shared memory
(FC, TPF, or Extension3) is not expanded for necessary
capacity.

8107

2E21

Executing

CMDRJE

The command ends abnormally because the shared memory
(SS3 or more) is not expanded for necessary capacity.

8108

2E21

Executing

CMDRJE

The program product is not installed.

9010

2E21

Executing

CMDRJE

The Fast Snap or Snapshot pair cannot be restored because
the volume that is set the S-VOL Disable is specified as the
P-VOL.

0079

2E30

Executing

CMDRJE

The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.

007A

2E30

Executing

CMDRJE

The command ends abnormally because the external volume
mapped for the online data migration is specified as the
S-VOL of a Fast Snap or Snapshot pair.

0081

2E30

Executing

CMDRJE

270 Troubleshooting