HP XP7 Storage User Manual

Page 223

Advertising
background image

Table 46 Command error messages (continued)

Value

Recommended action

Condition

Error

message

Error code

216

Please confirm the serial # of the
volumes by using the pairdisplay

A or Business Copy volume
is defined in the
configuration file

Extended CT group
across RAIDs

EX_EXTCTG

command to verify that the CT group

(HORCM_CONF) as a

is contained completely within one
RAID storage system.

group that extends across
storage systems.

215

Please confirm whether all CT groups
are already used by mainframe
volumes.

An available CT group for
OPEN Volume does not
exist.

No CT groups left
for OPEN Vol use.

EX_ENXCTG

214

Please confirm the CTGID using the
pairvolchk

command and confirm

The CT group references
within a group do not have
an identical CTGID.

Unmatched CTGID
within the group

EX_ENQCTG

that group references within the
configuration file (HORCM_CONF)
refer to the same CT group.

213

Please confirm whether
pair-operation is permitted on the

A device mentioned in the
configuration file does not

Permission denied
with the LDEV

EX_ENPERM

device by using the pairdisplay

have a permission for a
pair-operation.

or raidscan -find verify
command.

212

Please confirm volume size or
number of LUSE volume using the

Size of a volume is
unsuitable between the
remote and local volume.

Unmatched volume
size for pairing

EX_ENQSIZ

'raidscan -f' command, and make
sure the volume sizes are identical.

211

Please confirm if the type of storage
system is permitted for a RAID

A storage system (RAID)
mentioned in the

Permission denied
with the RAID

EX_ERPERM

Manager by using the inqraid
-CLI

and raidqry -h commands.

configuration file does not
have a permission for RAID
Manager.

209

Please confirm whether a target
volume is setting to SVOL disabling

A specified target volume for
SVOL is denied to become

SVOL denied due to
be disabling

EX_ESVOLD

y using inqraid -fl or

SVOL by the setting of Data
Retention.

raidvchkscan -v gflag
command.

210

Please confirm the microcode version
by using the raidqry -l
command.

The storage system does not
support a function for RAID
Manager.

Microcode not
supported

EX_ENOSUP

208

Please confirm the retention time for
a target volume that is set to Data

A target volume is denied to
be changing due to retention
time via LDEV guarding.

Mode changes
denied due to
retention time

EX_EPRORT

Retention by using raidvchkscan
-v gflag

command.

207

Please make the SLPR so that the
target port and the command device
belongs to the same SLPR.

A specified command device
does not have a permission
to access other SLPR.

Permission denied
with the SLPR

EX_ESPERM

206

Please release the pair of older
generations paired volume, or

Could not retain the pool for
executing a command due

Not enough Pool in
RAID

EX_ENOPOL

re-synchronize the pair of split status
paired volume.

to be exceeded the threshold
rate.

Error messages and error codes 223

Advertising
This manual is related to the following products: